The settings panel of the State statistics interface object is shown in the figures. The table describes the setting parameters of the State statistics interface object.

The Filters tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Filters tab

1

The Identification number*
field

Automatically

Displays the identification number of the State statistics object in the system

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the State statistics objects in the system

2

The Name*
field

Enter the value in the field

Sets the name of the State statistics object in the system

Latin alphabet, Cyrillic, and service characters

State statistics

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the State statistics object in the system


Boolean type

Clear

Setthe State statistics object is disabled and isn't used

Clearthe State statistics object is enabled and used

4

The Display
drop-down list

Select the value from the list

Sets the Display parent object for the given State statistics object

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Position group

5

The X field

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the State statistics window

% of the screen width

44

From 0 to M*100, where M is the number of the installed monitors

The Y field

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the State statistics window

% of the screen height

44

From 0 to M*100, where M is the number of the installed monitors

The W field

Enter the value in the field

Sets the width of the State statistics window 

% of the screen width

44

From 0 to M*100, where M is the number of the installed monitors

The H field

Enter the value in the field

Sets the height of the State statistics window 

% of the screen width

44

From 0 to M*100, where M is the number of the installed monitors

The  button

Click the button

Opens the window for changing the size and position of the State statistics window

NA

NA

NA

The Allow moving
checkbox

Set the checkbox

Allows moving the State statistics window using the mouse

Boolean type

Clear

Setallow moving the State statistics window using the mouse

Cleardisable moving the State statistics window using the mouse

The Monitor
drop-down list
Select the value from the list

Determines the number of the monitor in the system for which the coordinates are specified

Numbers of the monitors in OS1From 1 to 16

The Objects table

6The Type
drop-down list
Select the value from the list

Sets the type of the objects whose events must be displayed in the State statistics window

Available object typesNA

Depends on the objects registered in the system.

You can select only those object types that have the "INFORMATION" or "ALARM" value selected in the Processing messages column on the Events tab of the ddi.exe utility (see The Events tab)

The Event type drop-down listSelect the value from the listSets the events that must be displayed in the State statistics windowEvents available for the selected objectNADepends on the object type
The Color
drop-down list
Select the value from the list

Sets the color of the state displayed in the table and on the graph in the State statistics window

Color paletteBlackRGB color

Out of the group

7The Number of pixels fieldEnter the value in the fieldSets the number of pixels to be displayed on the state statistics graphInteger numbers0>=0

The DB tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1The Server fieldEnter the value in the fieldSets the name of the database server where the required database is storedLatin alphabet, Cyrillic, digits, and service charactersName of the server used by the systemDepends on the number of servers in the system
2The Folder
field
Enter the value in the fieldSets the name of the database where the events must be storedLatin alphabet, Cyrillic, digits, and service charactersName of the main database used by the systemDepends on the number of databases used by the system
3The User
field
Enter the value in the fieldSets the username to authorize on the database serverLatin alphabet, Cyrillic, digits, and service charactersNANA
4The Password
field
Enter the value in the fieldSets the password to authorize on the database server Latin alphabet, Cyrillic, digits, and service charactersNANA
5The Connection dialog buttonClick the buttonOpens the window to connect the database serverNANANA

The Interface tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1The Font buttonClick the buttonOpens the dialog for setting the text font in the table and on the graph (except for the legend—a short list or table with data) in the State statistics windowNANANA

*Name of the element isn't displayed in the settings panel of the given object