The settings panel of the Security zone object is shown in the figures with tabs. The tables describe the settings.

...

11

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Holidays 
field

Automatically

Displays the list of calendar days that are determined as holidays in Axxon PSIM

List of dates.
Date format: DD-MM-YY

NANA

2

The Add button

Click the button

Opens the Calendar window to select the date of a new holiday

NA

NA

NA

3

The Delete 
button

Click the button

Deletes the selected holiday date from the holidays list

NA

NA

NA

4

The Edit button

Click the button

Opens the Calendar window to change the date of the selected holiday in the list

NA

NA

NA

5The Protocol clear time fieldProtocol clear timeEnter the value in the field using the up and down buttonsSets the time of the day at which to start cleaning up the Event Viewer event viewerdatabase according to the Events archive length parameterHH:MM:SSCurrent system time at the moment of opening the object setting settings panel openingFrom 00:00:00 to 23:59:59

26

The Events archive length days
field

Enter the value in the field

Sets the number of days to store information about the events registered by Axxon PSIM and recorded into both the Event Viewer event viewer and the Incident incident server. This parameter affects all computers in a distributed system

Days

3

From
>=1

37

The Object codecode field

Enter the value in the field

Sets the number of the access control card, which is automatically displayed in the settings panel of the User object , when the object is created in the Object code field

Sequence of numbers

Not definedNA

More than one1

48

Starting configurationThe Starting configuration 
drop-down list

Select the value from the list

Sets the macro, which runs automaticallywhen starting Axxon PSIM 

Names of the Macro objects registered in the system

Not definedNA

Depends on the number of the Macro objects created in the digital the video surveillance system with distributed architecture

59

The Connections in architecturearchitecture checkbox

Set the checkbox

Sets the computers with which the created Computer object must exchange the data about the system configuration parameters: with all computers in the digital the video surveillance system with distributed architecture or only with the Computer object on the basis of which the given object is created

Boolean type

Clear

Setwhen creating you create a new computer, the Connection checkboxes in on the Architecture tab are set for all computers in the architecture

Clearwhen creating you create a new computer, the Connection checkbox in on the Architecture tab is set only for the computer from which this new object is created

610

The DNS instead of IP allowed
checkbox

Set the checkbox

Sets the address of the Serverserver/Remote Administrator’s workstation/Remote Client in client on the Architecture tab as DNS name, not only IP address

Boolean type

Clear

Set—when configuring you configure the interaction of the computers in the distributed system, you can specify the DNS name (instead of the IP address) of the Serverserver/Remote Administrator’s workstation/Remote Client in client instead of its IP address on the Architecture tab. At the same time, the verification of the entered address is disabled

Clear—when configuring you configure the interaction of the computers in the distributed system, specify the IP address of the Serverserver/Remote Administrator’s workstation/Remote Client in client on the Architecture tab

711The Ping (s) fieldEnter the value in the field

Sets the check period for the computer connection to the server

Note. For Serversservers, this value is saved automatically in the the CheckPingPeriod parameter. For the Remote Client, it is written client, you can specify the value manually in the the CheckPingPeriod parameter (see Registry keys reference guide)

Sequence of numbers10>=1
8Show documentation by clicking F1Set the checkboxEnables opening documentation in the pdf format by pressing the F1 button, when Axxon PSIM is running. The Administrator's Guide section is opened on the Server and the Remote Administrator’s workstation; the Operator's Guide section is opened on the Remote ClientBoolean typeClear

Set—the documentation is displayed by pressing the F1 button

Clear—the feature of displaying the documentation by pressing the F1 button is disabled

9Debug statisticsClick the buttonOpens the window with the events queue statisticsNANANA
10Administrator’s passwordClick the buttonOpen a dialog box for specifying the Administrator’s passwordNANANA
12

The

Internal synchronization: offline
checkbox

Set the checkbox

Enables the offline synchronization of the events

Boolean type

Set

Set—the offline synchronization is enabled. When the computer is reconnected, it gets all events for the no-connection time period

Clear—the offline synchronization is disabled. When the computer is reconnected, it doesn't get the events for the no-connection time period

The Internal synchronization: online
checkbox

Set the checkbox

Enables the online synchronization of the events

Boolean type

Set

Set—the online synchronization is enabled. The events Events are sent right after they occur according to the configuration parameters of the computer interaction in the distributed system

Clear—the online synchronization is disabled. The events Events aren't sent

12

Holidays

You can add the dates by clicking the Add button

List of calendar days which are defined as holidays in Axxon PSIM

Field with list of dates

Not defined

Date format: DD-MM-YY

13

Add

Click the button

Opens the Calendar dialog box to select the date of a new holiday

NA

NA

NA

14

Delete

Click the button

Deletes the selected holiday date from the Holidays list

NA

NA

NA

15

Edit

Click the button

Opens the Calendar dialog box to change the date of the selected holiday in the list

NA

NA

NA

13The Show documentation by clicking F1
checkbox
Set the checkboxEnables opening documentation in the pdf format by pressing the F1 button when Axxon PSIM is running. The Administrator's Guide section is opened on the server and the Remote Administrator's workstation; the Operator's Guide section is opened on the Remote clientBoolean typeClear

Set—the documentation is displayed by pressing the F1 button

Clear—the feature of displaying the documentation by pressing the F1 button is disabled

14The SMS confirmation
drop-down list
16SMS confirmationSelect the value from the listSets the Short Message object for the two-factor authentication—see Configuring two-factor authenticationNames of the Short Message objects registered in the systemNot definedNADepends on the number of the Short Message objects created in the system
15The Debug statistics button Click the buttonOpens the window with the events queue statisticsNANANA
16The Administrator’s password 
button
Click the buttonOpens the Set password window used for changing the administrator’s passwordNANANA

*Name of the element isn't displayed in the settings panel of the given object

The Date and time format tab:

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

171The Date format
drop-down list
Select the value from the list

Sets the format of the date format for displaying that is displayed in the Incident incident manager,  Operator operator protocol,and Video video surveillance monitor monitor in the current date field and when working you work with the archive

List of types of date format entry typesCurrent
  • Current—the date format set in the OS;
  • dd/MM/yy—the day/month/year format;
  • MM/dd/yy—the month/day/year format;
  • yyyy-MM-dd—the year/month/day format
182The Time format
drop-down list
Select the value from the listSets the time format for displaying in the Incident manager, Operator format of the time that is displayed in the incident manager, operator protocol,and Video video surveillance monitor monitor in the current date field and when working you work with the archiveList of types of time format entry typesCurrent
  • Current—the time format set in the OS;
  • HH:mm:ss24-hour format;
  • hh:mm:ss tt12-hour format

The RabbitMQ tab:

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

191The Server
field
Enter the value in the fieldSets the RabbitMQ server addressLatin charactersalphabet, digits, and service characterslocalhostServer IP address or name
202The Port
field
Enter the value in the fieldSets the RabbitMQ host server portNatural number seriesNon-negative integersNANot defined

From 0 to 65535

If the port is 0 or not specified, RabbitMQ won't run

213The User
field
Enter the value in the fieldSets the RabbitMQ host server usernameLatin charactersalphabet, digits, and service charactersguestDepends on the registered RabbitMQ users
224The Password
field
Enter the value in the fieldSets the RabbitMQ host server user passwordLatin charactersalphabet, digits, and service charactersguestDepends on the registered RabbitMQ users
235The Content-type
drop-down list
Select the value from the listSets the type of the sent/received contentSupported Available types of contentplain/text
  • application/json—a message in JSON format is sent;
  • plain/textThe Axxon PSIM event is sent in the "TYPE|ID|EVENT" format

The Password policy tab
Image Added

Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1The User password setting policy
checkbox
Set the checkboxChanges the user password settingsBoolean typeClear

Set—you can change the user password settings

Clear—you cannot change the user password settings

The User password policy table*

Note. The User password policy table* is active only after you set the User password setting policy
checkbox

2The Password length
field
Enter the value in the fieldSets the password lengthSequence of numbers8>0
The Small letters
drop-down list
Select the value from the listUses small letters when creating a passwordBoolean typeOK

OK—you can use small letters

No—you cannot use small letters

The Capital letters
drop-down list
Select the value from the listUses capital letters when creating a passwordBoolean typeOK

OK—you can use capital letters

No—you cannot use capital letters

The Use numbers
drop-down list
Select the value from the listUses numbers when creating a passwordBoolean typeOK

OK—you can use numbers

No—you cannot use numbers

The Symbols
drop-down list
Select the value from the listUses symbols when creating a passwordBoolean typeOK

OK—you can use symbols

No—you cannot use symbols

*Name of the element isn't displayed in the settings panel of the given object