Go to documentation repository
...
If the number of cameras connected to a video capture card is less than their maximum number, then you can reallocate them between ADCs of a video capture card. For this, those cameras whose frame rate you want to increase are allocated separately to one ADC or allocated in a number that is less than the maximum allowable one. Cameras allocated to a given ADC that aren't subject to strict frame rate requirements are reallocated to other ADCs.
An example of the allocating cameras to ADCs is shown in the figure.
...
To do this, place the selected camera in the priority process queue.
An example of the reallocation of resources of one ADC between cameras is shown in the figure below.
...
ADC operation mode is defined determined by the number of processed and digitized video signals. There are two modes:
...
To disable the Camera objects that correspond to the idle video channels in Axxon PSIM, do the following:
...
We recommend defining determining the actual frame rate of video signal digitization and then setting up the frame rate for video signals from video surveillance system cameras.
You must perform frame rate setup if frame rates of video signals from one or more cameras don't meet the requirements.
Actual frame rates are defined determined for each camera individually.
To define specify the actual frame rate for a selected camera, do the following:
...
Note that this information window displays initial data about the video stream from the camera or from the archive transmitted to the Video surveillance monitor. The actual displayed frame rate of the video stream can be different, see Displaying Display of information about a video stream on top of a video.
Info | ||
---|---|---|
| ||
For the Stretch video cards of standard compression (h264), the frame rate that is displayed on the Monitor in Axxon PSIM can be less than the frame rate that is indicated by the video card manufacturer. This is due to the fact that while displaying the frame rate of video signal digitization on the Monitor in Axxon PSIM blank frames that are distributed by the video card aren't taken into account. Blank frames don't contain the information about the image and are created by the video capture card when there are no changes in the video stream and a new video frame is the same as the previous one (for example, there is no motion in the frame). |
...
Task. Video signals on Camera 1 and Camera 5 must be digitized with an increased frame rate.
Initial data. The card has four ADCs. They are matched to four Video capture device objects in the object tree. The video capture card may have up to 16 cameras connected to it. 12 cameras are actually connected to the video capture card. The objects matched to the remaining four cameras are disabled. Each of the three ADCs, matched to the Video capture device 1, Video capture device 2, and Video capture device 4 objects, is configured to digitize the signals from four cameras. The ADC, matched to the Video capture device 3 object, isn't configured to digitize the signals from any camera. An example of the object tree is given in figure A.
...