Go to documentation repository
Page History
The settings panel of the Charts object is shown in the figure.
The description of the Table describes the setting parameters of the Chartsinterface object settings is shown in the table.
№ | Parameter | Method for |
setting the parameter value | Parameter description |
Representation | Default value |
Value range | ||||||
The Filters tab | ||||||
1 |
Identification number |
Automatically |
Displays the identification number of the Charts interface object in the system |
Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Chartsobjects in the system |
2 |
Name |
Enter the value |
into the field |
Sets the name |
of the Charts object in the system | Latin, Cyrillic and service characters |
Charts | A line containing a sequence of any |
characters (letters, digits, service |
characters |
except > and < |
characters), |
case- |
insensitive. Number of |
characters—from 1 to 60 |
3 |
Disable |
| Set the chechbox |
Displays the |
state (enabled or disabled) of the Charts object in the system | Boolean type |
Clear |
Set—the Chartsobject is disabled and |
isn't used Clear— |
the Charts object is enabled and |
used |
4 |
Display |
Select the value from the list |
Sets the Display parent |
object, to which the given Charts object |
belongs | Name of the Display objects registered in the system | Name of the Display parent |
object | Depends on the number of the Display objects in the system |
5 |
X |
Enter the value |
into the field | Sets the X coordinate in the |
horizontal axis for the upper left corner of the Charts interface |
window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
Y |
Enter the value |
into the field | Sets the Y coordinate in the |
vertical axis for the upper left corner of the Charts interface |
window | % of the screen height | - | From 0 to M*100, where M is the number of the installed monitors |
6 |
W |
Enter the value |
into the field | Sets the |
width of the Charts interface |
window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
H |
Enter the value |
into the field | Sets the |
height of the Charts interface |
window | % of the screen |
width | - | From 0 to M*100, where M is the number of the installed monitors |
7 |
The × button | Click the button | Opens a |
test window set the position of the Charts window |
- | - | - | |
8 |
Allow |
moving | Set the checkbox | Allows |
moving |
the Charts interface |
window manually | Boolean type |
No
Yes – manual moving is allowed.
No – manual moving is prohibited.
Clear | Set—allow moving the Charts interface window manually Clear—disable moving the Charts interface window manually | |
9 | Monitor | Select the value from |
the list | Sets the |
number of the monitor in the system for which the coordinates are |
specified |
Numbers of the monitors in |
OS | 1 | From 1 to 16 |
10 |
Number |
Select |
the value from the list | Sets the identifier of the Analog sensor object |
, the data from which |
should be displayed |
in the chart |
Sequence of numbers | - | Depends on the Analog sensor objects in the system |
11 |
Name |
Select the value from the list | Sets the name of the Analog sensor object, the data from which |
should be displayed |
in the chart | Names of the Analog sensor objects | - | Depends on the |
Analog sensor objects in the system |
12 |
Color |
Select |
the value from the list | Sets the display color |
of the corresponding analog sensor on the |
chart in |
the Charts |
interface window | Color palette | Black | RGB color |
13 |
Line width |
Enter the value |
into the field | Sets the width of the |
line |
in the chart | Sequence of numbers | 5 | >0 |
14 |
Number of pixels |
Enter the value |
into the field | Sets the number of pixels to be displayed |
in the |
chart | Sequence of numbers | 0 | >=0 |