The settings panel of the Charts object is shown in the figure.
The description of the Charts interface object settings is shown in the table.
№ | Parameter | Method for specifying the parameter | Parameter description | Symbol | Default value | Range of values |
---|---|---|---|---|---|---|
The Filters tab | ||||||
1 | The Identification number field | Automatically | Shows the identification number of the Charts object in the system | Positive integer | - | Depends on the number of Charts objects in the system |
2 | The Name field | Type-in the value in the field | Assigns the name to the Charts object | Latin, Cyrillic and service characters | Display manager | A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive Number of symbols – from 1 to 60 |
3 | The Disable checkbox | Set the chechbox | Shows the status (enabled or disabled) of the Charts object in the system | Boolean type | No | Yes – the Charts object is disabled and is not in use No – the Charts object is enabled and is in use |
4 | The Display dropdown list | Select from the list | Assigns the parent Display object, to which the given Charts object refers | Name of the Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system |
5 | The X filed | Type-in the value in the field | Sets the coordinate in the X horizontal axis for the upper left corner of the Charts interface object on the screen | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed |
The Y field | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the Charts interface object on the screen | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed | |
6 | The W filed | Type-in the value in the field | Sets the window width of the Charts interface object | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed |
The H field | Type-in the value in the field | Sets the window height of the Charts interface object | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed | |
7 | The X button | Click the button | Opens a sample box to set the Charts window position on the screen. | - | - | - |
8 | The Allow moving checkbox | Chechbox is set | Allows manual moving of the Charts interface box | Boolean type | No | Yes – manual moving is allowed. No – manual moving is prohibited. |
9 | The Monitor dropdown list | Select in the list | Sets the system ID of the monitor for which the coordinates are set | IDs of the monitors in the OS | 1 | From 1 to 16 |
10 | The Number drop-down list | Select in the list | Sets the Analog sensor object IDs, which readings should be displayed on the chart | Positive integer | - | Depends on the Analog sensor objects in the system. |
11 | The Name field | Automatically | Sets the name of the Analog sensor object, which readings should be displayed on the chart | Names of the Analog sensor objects | - | Depends on the object type |
12 | The Color drop-down list | Select in the list | Sets the color to highlight the corresponding analog sensor on the graph in the Charts window | Color palette | Black | RGB color |
13 | The Line width field | Type-in the value in the field | Sets the cart line width | Integer | 5 | >0 |
14 | The Number of pixels field | Type-in the value in the field | Sets the number of pixels to be displayed on the graph | Sequence of numbers | 0 | >=0 |