Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Keyboard object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Keyboard object in the video surveillance system with

the

distributed architecture

Sequence of numbers

NA

From 1 and above.

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Keyboard objects in the video surveillance system with

the

distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the Keyboard object in the video surveillance system with

the

distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Keyboard

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Keyboard object in the video surveillance system with

the

distributed architecture

Boolean type

Clear

Setthe Keyboard object is disabled and isn't used

Clearthe Keyboard object is enabled and used

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object of the system with

the

distributed architecture to which the given Keyboard object belongs

Name

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the video surveillance system with

the

distributed architecture

The Settings group

5

The X field

Enter the value in the field

Sets the coordinate on the horizontal X axis of the upper left corner of the object selection window to which the given command refers

% of the screen width

NA

From 0 to 100%


6

The Y field

Enter the value into the field

Sets the coordinate on the vertical Y axis of the upper left corner of the object selection window to which the given command refers

% of the screen height

NA

From 0 to 100%


7

Control devices*

Set the switch in the required

radio button

position

Sets the

interface

objects that

you

can

control using the Keyboard

be controlled using the keyboard

List of device types for control

Operate all

Operate all—the

Operator

operator can control all

interface

objects according to the settings in the

 Keyboard configuration

keyboard configuration file 

From list—the

Operator

operator can control only those

interface

objects that are specified in the list below

8

The Type
drop-down list

Select the value from the list

Sets the type of the

interface

object that

you

can

control

be controlled using the 

Keyboard

keyboard

Name


Names of the object types registered in the system

NA

Depends on the number of the

interface

object types created in the video surveillance system with

the

distributed architecture

9

The Number
drop-down list

Select the value from the list

Sets the identification number of the

interface

object that

you

can

control using the Keyboard

be controlled using the keyboard

Sequence of numbers

NA

Depends on the number of the created devices of the type selected in item 8

 

in the video surveillance system with

the

distributed architecture

10

The Name
drop-down list

Automatically

Indicates the name of the

interface

object that

you

can

control using the Keyboard

be controlled using the keyboard

Name of the objects of the selected type registered in the system

NA

Depends on the number of the created devices of the type selected in item 8

 

in the video surveillance system with

the

distributed architecture

*Name of the element doesnisn't appear displayed in the settings panel of the given object.