The interface windows are not being aren't displayed on the Server or the Remote Client in the following cases:
The corresponding Screen object is not being isn't assigned to the required computer.
Tip The full article: Placing the interface components on the screen Assigning the displays to the operator workstations
The corresponding Screen object or interface object are being is prohibited by the rights of the current user’s rightsuser.
Tip The full article: Limiting access to the system objects administration, control and viewing functions
The ports are being closed for the required interface objects.
Tip The full article: The list of TCP ports used in INTELLECT™INTELLECT
The wrong Screen object was selected for display. Click the Interfaces button on the Main control panel and select the correct Screen.
Tip The full article: Main control panel
Windows 10/11 update can also be the reason why interface objects aren’t displayed. For example, if KB5020695, KB5019961, KB5020617 updates were installed, Windows may stop initializing the previously configured printers. Since the printers are used by some interface objects, the display problems occur. To fix this, you need to reconfigure the connection to the printers in Windows and restart Intellect.