Go to documentation repository
Page History
Tip |
---|
Video stream and scene requirements for the Glow detector |
To configure the Glow detector, do the following:
- Go to the Detection Tools tab
- Detectors tab.
- Below the required camera, click
- click Create… → Category: Production Safety → Glow detector.
By default, the detection tool detector is enabled and set to track light sources (lamps).
If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Object features | ||
Video stream | Main stream | If the camera supports multistreaming, select the stream for which detection is needed. Selecting a low-quality video stream reduces the load on the Server |
Other | ||
Enable | Yes | The detection tool detector is enabled by default. To disable the detection tooldetector, select the the No value value |
No | ||
Name | Glow detector | Enter the detection tool detector name or leave the default name |
Brightness threshold | 240 | Specify the sensitivity of the detection tool detector to changes in the state of the light source. You must select the required value empirically. For a dim light source, we recommend increasing the value of the parameter. The value must be in the range [0, 255] |
Decoder mode | Auto | Select a processing resource for decoding video streams. When you select a GPU, a stand-alone graphics card takes priority (when decoding with NVIDIA NVDEC chips). If there is no appropriate GPU, the decoding will use the Intel Quick Sync Video technology. Otherwise, CPU resources will be used for decoding |
CPU | ||
GPU | ||
HuaweiNPU | ||
Number of frames processed per second | 20 | Specify the number of frames that the detection tool detector will process per second. The value must be in the range range [0.016, 100] |
Sensitivity | 99 | Specify the sensitivity of the detection tool detector as a percentage. You must select the required value empirically. The higher the sensitivity, the greater the probability of a false alarmevent. The lower the sensitivity, the greater the probability of missing an event. The value must be in the range [0, 100] |
Time delta between frames | 100 | Specify the time interval between two measurements of light indication in seconds. The value must be in the range [0, 10000] |
Type | Glow detector | Name of the detection tool detector type (non-editable field) |
To ensure receiving that you receive accurate events from the detection tooldetector, in the preview window window you can specify one or more detection areas using the anchor points (see Configuring a detection area). Detection areas must be located on each light source (lamp) and their dimensions must match the dimensions of the light sources.
Info | ||
---|---|---|
| ||
|
To save the parameters of the detection tooldetector, click the Apply button. To To cancel the changes, click the Cancel button.
Configuration of the Glow detector is complete.