The Detection of light indication control module is configured using the System settings menu, on the Hardware tab, on control module registers turning on and off of light indication in the camera FOV.
Configuration of the Detection of light indication control module includes: selection of detection areas, specifying the parameters of the detection tool.
You can configure the Detection of light indication control module on the settings panel , using the Camera settings.
Image Removed
The of the Detection of light indication control module is configured as follows:object that is created on the basis of the Camera object on the Hardware tab of the System settings dialog window.
Image Added
Selecting detection areas
- Go to the settings panel of the Detection of light indication control settings panelcontrol object.

- Click the the Settings button (1). The Detection settings window will openopens.

- Specify the location of lights sources in the image which should be tracked by detection:Click the In the Detection settings window, click the Stop video button to pause the playback and capture the video image.
- On the captured video image, specify areas to be analyzes (1). Click the left mouse button in the frame area and stretch it the location of the light sources that you want to monitor with the detection tool. For this, on the captured video image, specify the detection areas by clicking in the frame and stretching the bounding box to the required size. The minimal allowed size of the analyzed area is 15x15 pixels. The maximum allowed size of the analyzed area is 200x200 pixels.
Areas of interest detection areas are numbered in the order of creation, starting from 1. The number of analyzed area is not limited. Adding the area at the right from the video image the corresponding button is displayed (2).
Image Removed - Specify the required size, shape and location of sectors in the area of interest moving their borders. Selecting the area take into account that the local change of illuminance and specular surface near lamps in the area of interest can cause the false detection triggering.
To specify the area again, click When you add an area, the button corresponding to this area is displayed to the right of the video image.
Image Added
Info |
---|
|
- The number of detection areas is unlimited.
- You can change the size and position of detection areas by moving their borders with the mouse.
- Note that changes in local illumination and reflective surfaces near lamps that are in the detection area can cause false triggering of the detection tool.
- To correctly specify a detection area, you must include in it a small part of the area near the light source.
- To change the borders of a detection area, activate it by clicking the button with its number in the list of areas
|
...
- (the button will change its color to blue) and resize the area
|
...
...
...
- To delete an area, click the
Image Added button to the
|
...
- right of the area number.
|
...
Parameters of the detection
...
tool
- Go to the Parameters tab in the Detection settings window (1).
Image Modified - Using the up-down buttons, enter the value of sensitivity parameter in the Sensitivity field (2). The optimal value is selected In the Sensitivity field, specify the sensitivity of the detection tool to the change of the video image in the range from 0 to 100. You must select the optimal value experimentally by testing detection on triggering in the required conditions. The value range is from 0 to 100. The more sensitivity the more possibility higher the sensitivity, the higher the probability of false triggering. The less lower the sensitivity, the more possibility of losing event.greater the probability of missing an event. The default value is 85.
- In the Brightness sensitivity field, specify the sensitivity of the detection tool to the change of the light source state. The default value is 240. You must select the optimal value experimentally by testing detection on triggering in the required conditions. For a dim light source, we recommend increasing the value of the parameter.
- In the Time between measurements (ms) field, specify in milliseconds the time interval between two measurements of light indication. The default value is 1000.
- Click the OK button (3) to save the changes and return to close the Detection settings window.
- On the settings panel of the Detection of light indication control.On the Detection of light indication control settings panel object, click the Apply button (2)the Apply
Image Added button to save the changes.
Configuring the Detection of light indication control module is complete.