To configure create the Multiple Objects objects detector, do the following:
- Create the required detection tool
- detector and specify its parameters (see Configuring detectors and their sub-detectors).
- Below the created detection tool
- detector, click
- click Create… → Multiple Objects
- objects.
By default, the detection tool detector is enabled and set to generate events when the number of objects in the detection area exceeds the value specified in the detection tool detector settings.
If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:
Parameter | Value | Description | |||||
---|---|---|---|---|---|---|---|
Other | |||||||
Enable | Yes | The detection tool detector is enabled by default. To disable the detection tooldetector, select the the No value value | |||||
No | |||||||
Name | Multiple Objects objects | Enter the detection tool detector name or leave the default name | |||||
Type | Multiple Objects objects | Name of the detection tool detector type (non-editable field) | |||||
Basic settings | |||||||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool detector to generate an event. The value must be in the range [0.05, 100]
| |||||
Maximum object speed | 500 | Specify the maximum object speed per second for the detection tool detector to generate an event. The value must be in the range [0, 500]
| |||||
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool detector to generate an event. The value must be in the range [0.05, 100]
| |||||
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool detector to generate an event. The value must be in the range [0.05, 100]
| |||||
Minimum object speed | 0 | Specify the minimum object speed per second for the detection tool detector to generate an event. The value must be in the range [0, 500]
| |||||
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool detector to generate an event. The value must be in the range [0.05, 100]
| |||||
Number of alarm objects | 10 | Specify the number of objects for the detection tool detector to generate an event. The value must be in the range [1, 100]. | |||||
Object class | All classes | Select the object class that must generate an event. The default value is is All classes
| |||||
Vehicle | |||||||
Person |
By default, the entire frame is the a detection area. In If necessary, in the preview window, you can specify the detection areas using the anchor points can reduce the detection area (see Configuring a detection area) and/or set one or more skip areas (see Configuring a detection skip area).
Info | ||
---|---|---|
| ||
|
To save the parameters of the detection tooldetector, click the Apply button button. To cancel the changes, click the Cancel button button.
Configuration of the Multiple objects detector is complete.