Parameter

Method of setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number

Automatically

Displays the identification number of the Web-server object in the digital video surveillance system with the distributed architecture

Sequence of numbers

-

From 1 and above.

Depends on the number of the Web-server objects in the digital video surveillance system with the distributed architecture

2

Name

Enter the value into the field

Sets the name of the Web-server object in the digital video surveillance system with the distributed architecture

Latin, Cyrillic and service characters

Web-server

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Web-server object in the digital video surveillance system with the distributed architecture

Boolean type

Clear

Setthe Web-server object is disabled and isn't used

Clearthe Web-server object is enabled and used

4

Computer

Select the value from the list

Sets the Computer parent object of the digital system with the distributed architecture, to which the given Web-server object belongs

Name of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture

The HTTP-server group

5



Port number

Enter the value into the field

Sets the number of the port used by the HTTP-server (used for video surveillance via a web browser, including via the internet)

Sequence of numbers

80

Any valid unused port numbers.

The number of ports is determined by the system administrator.

Number of connections

Enter the value into the field

Sets the maximum possible number of connections to the Server via the Web-server module.

Each request to view the video signal from each camera and each request to control all PTZ devices regadless of their number is considered as a connection

Sequence of numbers

100

Any integer.

If 0 value is specified in the Video surveillance monitor of the Web-server module, video signals won't be displayed

Parallel exports

Enter the value into the field

Sets the maximum allowed number of archive files to be uploaded simultaneously

Sequence of numbers

2Any integer number

From 1 and above.

If you leave the field blank, the lowest possible value is used

The HTTPS-server group

6




Use HTTPS protocol

Set the checkbox

Enables the HTTPS protocol when transmitting data via the Web-server

Boolean type

Clear

Set—the HTTPS protocol is used

Clear—the HTTPS protocol isn't used

Key

Enter the value into the field

Key for data transmission via the HTTPS protocol

Latin, Cyrillic and service characters

C:\Program Files (x86)\ Axxon PSIM\Modules\SSL\ssl_internal.key

Depends on the location of data encryption key when transmitting data via the HTTPS protocol

Certificate

Enter the value into the field

Certificate for data transmission via the HTTPS protocol

Latin, Cyrillic and service characters

C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.cert

Depends on the location of certificate file when transmitting data via the HTTPS protocol

Port number

Enter the value into the field

Sets the number of the port used for HTTPS-server (used for video surveillance in a web browser and in the internet)

Sequence of numbers

443

Any available unused port numbers.

The number of ports is specified by the system administrator

Not in a group

7

Default user

Select the value from the list

Sets the user with rights and authority to conduct the video surveillance from the Remote workstation using the Web-server module

Names of the users registered in the system and added to the rights

Not defined

Depends on the number of the users registered in Axxon PSIM

8

ECHD translation

Set the checkbox

Enables to use the http requests used for integration with ECHD

Boolean type

Clear

Setrequests used for integration with ECHD are run for the Camera objects on the basis of which the ECHD channel objects are created

Clearrequests used for integration with ECHD are not run

9Use NAT addressSet the checkboxEnables the router address substitution in the ECHD requestsBoolean typeClearSet—when requesting the URL of streams via the HTTP API, the IP address of the router specified in the settings panel of the RTSP-Server object is substituted in the response to the request

Clear—when requesting the URL of streams via the HTTP API, the IP address of the Server in its local network is returned in response to the request

...