Go to documentation repository
Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.
Previous page Next page
Intellect Web Report System
XML file | Parameter | Available values | Default | Parameter in effect |
---|---|---|---|---|
<Directory of the Intellect software installation>\Modules\Wt2\Web.config | CamMonitorShift | -5000 - 5000 | 0 | Sets shifting of video start while report viewing in milliseconds: >0 – video will start later than time specified in a report <0 – video will start earlier than time specified in a report |
FaceReplaceCameraIpFrom | IP-address | - | Changes internal IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside | |
FaceReplaceCameraIpTo | IP-address | - | Changes external IP-address of a Server specified in the Architecture while viewing video for POS reports and for "Face" module report from outside |
Overview