Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

The settings panel of the User permissions  object is shown in the figure.

Elements of the settings panel of the User permissions  object are described in the table.

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

The ID field*

Automatically

Displays the identification number of the User permissions  object in the system

Sequence of numbers

-

Depends on the number of the User permissions  objects in the system.

2

The Name field*

Enter the value in the field

Sets the name of the User permissions  object in the system

Latin, Cyrillic and service characters

User permissions

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

The Disable checkbox

Set the checkbox

Defines the status of the User permissions  object (enabled or disabled) in the system

Boolean type

No

Yes – the User permissions object is disabled and is not in use.

No – the User permissions object is enabled and is in use.

The Configuring group

4

The group of Tabs* checkboxes

Set the checkbox

Specifies the tabs of the System settings dialog box that can be accessed when the User gets the corresponding rights

Boolean type

All checkboxes are set unchecked

The following values are available for each tab:

Yes – User is allowed to manage the objects in the tab.

No – access to the tab is forbidden.

5

The Ask user password for shutdown system checkbox

Set the checkbox

Allows shutting down Intellect using the password of the authorized User

Boolean type

No

Yes – User with these rights is allowed to shut down Intellect

No – User with these rights is not allowed to shut down Intellect

6

The Ask administrator password for system shutdown checkbox

Set the checkbox

Allows shutting down Intellect using the password of the Administartor

Boolean type

No

Yes – Intellect shuts down only when the Administrator password is in use

No - Intellect shuts down in various ways

7

The Forbid to hide interface checkbox

Set the checkbox

Allows hiding interfaces in Intellect

Boolean type

No

Yes – interfaces cannot be hidden

No – interfaces can be hidden

8

The Relogin prohibited checkbox

Set the checkbox

Allows changing the user in Intellect

Boolean type

No

Yes – User can be changed

No – User cannot be changed

9

The list of system objects*

Automatically

Displays the objects created in the system and allows setting the administration and monitoring rights

-

-

-

The Connection with AD group
10The Connection with AD buttonClick the buttonOpens a dialog box to configure correspondence between Intellect user permissions and Windows Active Directory---

The Access to archive group

11

The Depth __ last hours field

Enter the value in the field

Sets the number of last hours of video archive that can be viewed

Nonnegative integer

-

>=0

0 means that viewing the archive is prohibited  

12

The Since last access checkbox

Set the checkbox

Sets the time to define the archive depth

 

Boolean type

No

Yes – hours available for viewing are counted since the User logged in

No - hours available for viewing are counted since the current moment

The Access to backup archive group

13

The Depth __ last hours field

Enter the value in the field

Sets the number of last hours of backup archive that can be viewed

Nonnegative integer

-

>=0

0 means that viewing the backup archive is prohibited 

14

The Since last access checkbox

Set the checkbox

Sets the time to define the backup archive depth

Boolean type

No

Yes – hours available for viewing are counted since the User logged in

No - hours available for viewing are counted since the current moment

No group

15

The Allow video archive files remove checkbox

Set the checkbox

Defines whether video archive files can be removed from  the Monitor interface

Boolean type

No

Yes – The “Remove video from the feature menu” item is available in the Monitor

No – removing video from the feature menu is not available

16The Allow rewrite protection checkboxSet the checkboxSets possibility of rewrite protecting of filesBoolean typeYes

Yes – operator added to these permissions can protect archive records against loop recording

No – operator cannot protect archive records against loop recording
17The Allow to disable file protection checkboxSet the checkboxSets possibility to disable rewrite protection of filesBoolean typeYes

Yes – operator added to these permissions can reset rewrite protection of files

No – Operator can't reset rewrite protection of files
18The Allow export checkboxSet the checkboxSets possibility to export protected recordsBoolean typeYes

Yes – Operator added to these permissions can export video recordings.

No – Operator cannot export video recordings.
19The Log out if inactive for __ minutes checkbox and field
Set the checkbox, enter the value in the field

Sets the time period (in minutes) when the operator is inactive - at the end of this period the session is to be terminated

Boolean type, integerNo

Yes – when the operator is inactive for the specified time period, session is not automatically terminated. To continue operation, log in the system specifying the username and password. 

No – session is not automatically terminated when the operator is inactive.

20The ONVIF dropdown list
Select the value in the listSets user rights to use the ONVIF ServerSupported types of permissions-

Administrator

Operator

User

21The Import rights button
Click the buttonConfigure import of user permissions settings from several other User permissions objects.---

* The name of the object is not displayed on the settings panel 