The Uragan module can be set to record the video image received by the camera. If this function is enabled, the recording starts automatically when the LPR channel recognizes an LP number. The duration of the recording can also be specified.
Note. In case of heavy traffic, when subsequent LP numbers are registered in a time period smaller than that specified, the video signal is recorded continuously.
To enable automatic recording functionality and to specify the recording duration, do the following:

  1. In the System Settings dialog window, open the Hardware tab.
  2. Select the LPR channel, corresponding to the activated program module, in the objects tree on the Hardware tab (see. «Program module activation, used for Plates identification», see Fig. 7.2—9, 2). The settings panel of the selected object will open on the right side of the window.


Fig. 7.2—9 Setting up the parameters of automatic video recording

  1. Check the Auto record checkbox to enable recording the video upon recognizing an LP number.
  2. In the field next to the checkbox, specify for how many seconds the video should be recorded after LP number recognition.

Note. Zero (0) in this field means that the recording starts at the moment of LP recognition and continues indefinitely.

  1. Click Apply.

The auto recording setup is complete.