The External Plates Database object settings panel includes the following interface elements:
Fig. 8.4—1 The object settings panel «external Plates Database»
Table 8.4—1describes the elements of the External Plates Database object settings panel.
Table 8.4—1
№ |
Parameter name |
Parameter setting method |
Description |
Data type |
Default value |
Value range |
---|---|---|---|---|---|---|
1 |
Text field «Data source connecting string» |
Automatically, after setting up the connection |
Connection string to the external database |
Latin and special symbols |
- |
A sting, containing a sequence of characters (letters, digits, characters)non case-sensitive |
|
Text field «Table» |
Automatically, after setting up the connection |
Plates table name in the database |
Latin and special symbols |
- |
A sting, containing a sequence of characters (letters, digits, characters)non case-sensitive |
|
Text field «Field» |
Automatically, after setting up the connection |
Plates table name in the database |
Latin and special symbols |
- |
A sting, containing a sequence of characters (letters, digits, characters)non case-sensitive |
|
Button «Configuration» |
Press the button |
Access to connection settings |
- |
- |
- |
2 |
Dropdown list «Search method » |
Select the value from the list |
Search method selection of identified number in the external database |
A list of available search methods |
exact fit |
Partial search at plate's part– the found cites containing a key word in any position and order are returned |
3 |
Text field «Partial or wildcards search returns no more than» |
Enter the value in the field |
Setting the number of returned results while doing a partial search at plate's number or a wildcard |
integer |
5 |
1 - 1000 |
4 |
Button «Edit SQL-query» |
Press the button |
Access to SQL-query, used in the search method «SQL-query» |
- |
- |
- |
5 |
«Process recognized LPs received only from local recognizers» chechbox |
Set the checkbox |
Specifies the mode when LPs only from local recognizers are processed |
Boolean type |
No |
Yes – the mode when LPs only from local recognizers are processed is enabled. |
6 |
«Extended mode» checkbox |
Set the checkbox |
Enables the extended mode |
Boolean type |
No |