Settings panel of the Server of Control object is given on figure ( Fig. 8.3—1).
Fig. 8.3—1 Settings panel of the Server of Control object
Description of the Server of Control object settings panel elements is given in table (Tab. 8.3—1).
Tab. 8.3—1 Elements of settings panel of the Server of Control object

#

Name

Method for setting the parameter value

Description

Type

Default value

Value range

 

1

Identifier

Automatically

Shows the identification number of the Server of Control object in the system

Nonnegative integer

-

>=0

 

2

Name

Enter the value in the field

Shows the name of the Server of Control object in the system

Latin, Cyrillic letters and service characters

Server of Control

A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.
Number of symbols – from 1 to 60.

 

3

Computer

Is selected in the list

Assigns the parent Computer object for the Server of Control object

Name of the Computer objects registered in the system.

Name of the parent Computer object

Depends on the number of the Computer objects in the system.

 

Advanced group

 

 

 

 

 

 

4

Snapshots/video...

Click the button

Opens a dialog box for configuring reaction to snapshots and videos receiving on sensors alarms at the Agent of Control

-

-

-

 

Event log group

 

 

 

 

 

 

5

auxiliary characters

Is set in a checkbox

Enables logging of auxiliary characters at the transport level into the event log

Boolean

False

True - logging of auxiliary characters is enabled
False - logging of auxiliary characters is not performed

 

6

alarms

Is set in a checkbox

Enables logging alarms into the event log

Boolean

True

True - logging of alarms is enabled
False - logging of alarms is not performed

 

7

system status

Is set in a checkbox

Enables logging of events related to system status

Boolean

True

True - logging of events related to system status is enabled
False - logging of events related to system status is not performed

 

8

Archive period (h)

Enter the value in the field

Sets the frequency at which the event log is to be archived

Hours

48

>0

 

9

File size (MB)

Enter the value in the field

Sets the file size threshold upon which the event log is archived. This setting overrides the value in the Archive frequency field.

Megabytes

100

>0

 

10

Keep archives for (months)

Enter the value in the field

Sets the length of time for which you want to store archived event logs.

Months

3

from 1 to 24

 

Transfer group

 

 

 

 

 

 

11

TCP/IP port (Agent)

Enter the value in the field

Sets the port number for TCP/IP communication with remote objects of Agent of Control

Nonnegative integer

7777

from 1 to 65535

 

12

TCP/IP port (Archive)

Enter the value in the field

Sets the port number for TCP/IP communication with remote Search in archive module

Nonnegative integer

7755

from 1 to 65535

 

13

First COM port number

Is selected in the list

Sets the first COM port number

COM-ports names

Com1

from Com1 to Com256

 

14

Number of COM ports

Is selected in the list

Sets number of COM ports used

Nonnegative integer

1

from 1 to 256

 

15

COM port speed

Is selected in the list

Sets the COM port speed

Baud

9600

110
300
1200
2400
4800
9600
19200
38400
57600

 

16

COM port format

Enter the value in the field

Sets the COM port format

COM port format

8N1

  • first digit: from 5 to 9 data bits;
  • second letter: N (No parity) - no parity bit, E (Even parity) - even parity bit, O (Odd parity) - odd parity bit;
  • third digit: 1 or 2 stop bits.

 

Outside the groups

 

 

 

 

 

 

17

Restart

Click the button

VideoSrv communication module restarting

-

-

-

 

18

Partition of Control objects

Using the Add, Edit and Delete buttons

Displays the list of Partition of Control objects for which monitoring of status is performed from the Server of Control

-

-

-

 

19

Sort by

Is selected in the list

Sets the sorting method for Partition of Control objects in the table

Sorting methods

ID

ID
Object code
Name

 

20

>

Click the button

Apply the sorting method selected in the Sort by list

-

-

-

 

21

Add...

Click the button

Opens a dialog box to add a Partition if control object into the list

-

-

-

 

22

Edit...

Click the button

Opens a dialob box to change a Partition of control object in the list. The window is the same as for adding a Partition of control object

-

-

-

 

23

Delete

Click the button

Deletes a Partition of control object from the list

-

-

-

 


  • No labels