BioSmart 4 controller working with external hardware is configured on the settings panel of the BioSmart 4 object:
- In the Additional hardware list select the type of device connected to the port of controller 2
(Table 3.32, Fig. 3.32, 1).
Fig. 3.3 2 Configuring BioSmart 4 controller working with external hardware
Table 3.3 2 Additional hardware
Additional hardware |
Description |
None |
Additional hardware is not connected |
BioSmart relay control unit |
BioSmart relay control unit is connected to the controller |
SK-24 |
Key storage device is connected to the controller |
Kronwerk |
Controller works in the Kronwerk integration mode under control of Kronwerk software |
BioSmart BOX |
BioSmart BOX is connected to the controller |
Perco |
Controller works in the Perco integration mode under control of Perco software |
- In the Wiegand exit list select the protocol type of Wiegand output of BioSmart 4 controller (Table 3.33, Fig. 3.32, 2).
Table 3.3 3 Protocol type of Wiegand output of BioSmart 4 controller
Additional hardware |
Description |
None |
No third-party controller is connected to Wiegand output of BioSmart 4 controller |
Wiegand 26 |
Third-party controller that uses Wiegand 26 protocol is connected to Wiegand output of BioSmart 4 controller |
Wiegand 32 |
Third-party controller that uses Wiegand 32 protocol is connected to Wiegand output of BioSmart 4 controller |
- In the Wiegand entry list select the protocol type of Wiegand input of BioSmart 4 controller (Fig. 3.32, 3).
- To enable the bypass mode set the On value for the corresponding parameter (Fig. 3.32, 4). In this case the card that is not registered in the database of ACFA Intellect can be transferred to the third-party controller via Wiegand output of BioSmart 4 controller.
- Click the Apply button to save all changes.