To configure discrete and alarm inputs of controller, do the following:
- Click the Entry parameters on the settings panel of the BioSmart PROX object.
- Set the following parameters for each discrete input:
- In the Active level list select the level of signal at discrete input at which the access sensor triggering is detected (Fig. 3.43, 1).
Fig. 3.4 3 Configuring discrete and alarm inputs of BioSmart PROX v.2 and BioSmart PROX-E controllers
- In the corresponding list select the relay of controller that is event-triggered on the discrete input (Fig. 3.43, 2).
- In the Event list select the type of event processed by controller when the signal of specified level arrives to discrete input (Table 3.42, Fig. 3.43, 3).
Table 3.4 2 Type of event processed by controller
Event type |
Description |
Not assigned |
Signals from corresponding discrete input are not processed |
Relay control button |
Signal of specified level caused by pushing the button is processed |
Access sensor |
Signal of specified level caused by walking through the turnstile or the door is processed |
Unlocking sensor |
Signal of specified level caused by unlocking the relay is processed |
- In the Timer field specify time (in milliseconds) of active state of the relay after its triggering (Fig. 3.43, 4).
- Specify the following parameters for each alarm input:
- In the Active level list select the level of signal occurring at alarm input – it triggers access sensor (Fig. 3.43, 5).
- In the Event list select the type of sensor which triggering causes controller action (door locking, door unlocking, fire alarm activation, Fig. 3.43, 6).
- Click the OK and then the Apply button.
Discrete and alarm inputs of controller are now configured.