To configure a Microtrack train in ACFA Intellect, go to the settings panel of the Microtrack control segment. To find the settings panel, go to the Settings dialog box, click the Hardware tab, and browse the object tree of the relevant Microtrack Train object (Fig. 3.5—1).
Fig. 3.5—1 A Microtrack Control Segment object
To configure a Microtrack control segment:

  1. Go to the settings panel of the Microtrack Control Segment object (Fig. 3.5—2).


Fig. 3.5—2 Configuring a Microtrack control segment

  1. In the Start field, use the up arrow and down arrow buttons to indicate the number of the subcell that matches the key point where the control segment begins (see Fig. 3.5—2, 1).
  2. In the Finish field, indicate the number of the subcell that matches the key point where the control segment ends (see Fig. 3.5—2, 2).

Note: TheStart and Finish fields can contain values in the range1…143. Try to not let control segments overlap.
Attention! The value in the Finish field must not be larger than the value in the Start field.

  1. Click Apply.

Configuration of the Microtrack II control segment is now complete.