Intellect's core interacts with functional modules (third party information systems) according to the following connection parameters:

  1. Port number.
    1. For the video subsystem: 900.

    2. For the Interface IIDK object: 1030.

    3. For ATMs: 1009.

  2. The IP address of the computer that is running Intellect's core.

  3. ID (the connection object ID).

Attention!

For connecting to the video subsystem (port number 900), the ID must be greater than 1 and may not equal the ID of the cameras. For the IIDK Interface object (port number 1030), the ID is equal to the object ID set in Intellect's setup dialog box.

Note:

If an MDL file exists (see Section Creating MDL files), the connection to Intellect's core does not require creating the IIDK Interface object in the system. The connection ID passed is an empty string (in other words, the ID is "").