Purpose of integration the Intellect software package with FSA/ACS device

  • Provide user interface on the same software in the context of different security equipment subsystems.
  • Configure cause-and-effect connection between different subsystems (video surveillance, FSA, ACS, audio registration, etc.).
  • Use network capability of the software.
  • Joint marketing promotion of integrated solution by software and hardware manufacturers.

Integration technology:

Technologically integration is a synchronization of information streams between software and FSA/ACS hardware. There are four main information streams between software and FSA/ACS hardware.

  • Hardware events.
  • Software control.
  • Software configuration. Send configuration from Hardware (auto configuration).
  • Request-response of current hardware state.

Ways of integration:

  1. Low-level protocol. Events, reactions, configuration commands as the byte set are programmed to the software.
  2. SDK – Software Development Kit. Events, reactions, configuration commands, state requests as functionas are programmed to the software.
  3. Communication server (Program-driver) – program layer between ITV | AxxonSoft software and hardware in which events, reactions, configuration commands, state request are built in. COM-server and OPC-server are examples of these programs.
  4. SOFT-SOFT. Events, reactions, configuration commands, state requests are programmed on the level of two software packages. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. for access to event log.
  5. Universal protocol integration: OPC, SNMP, BACnet. Exchange of events, reactions, configuration commands and state requests with hardware is performed by general protocol. List of hardware connected to the Intellect software package by universal protocols is specified in the Systems connected by universal protocols section.

Integrated hardware

FSA systems

Common name

Integrated hardware (name of devices)

Restrictions (monitoring, control, configuration)

Name in price-list

Information on manufacturer

Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT)

Connection interface (RS-232, TCP\IP)

POLON ALPHA

 

Polon4500, Polon4900, TSR, ROP, EKS, EWK, SAL, UCSMonitoring Polon-Alfa Spółka
z ograniczoną odpowiedzialnością Sp.k.
ul. Glinki 155 85-861
Bydgoszcz, Poland
E-mail: polonalfa@polon-alfa.com.pl
Tel: +48 52 36 39 263
low-level protocolRS-232
SatelINTEGRA 128, Satel CA64.Monitoring SATEL
ul. Schuberta 79
80-172 Gdansk, Poland
tel. +48 58 320-94-00
fax +48 58 320-94-01
e-mail: satel@satel.pl
www.satel.pl
low-level protocolRS-232
AritechFP2000Monitoring, control 

Aritech 
Peschaniy karier, 3-16
Moscow
109383 

Tel.: (495) 785-43-41, (495) 036-8694 
E-mail: info@aritech.pro 
www.aritech.pro

low-level protocolCOM port
UniPOSIFS – 5000, 7000, 7203-O, 7203-IO, 7203-R, 7203-OCMonitoring, configuration, control 1784 Sofia, Bulgaria
Mladost 1, block 56
Tel. + 359 (0)2 97 444 69 
Office_sofia@unipos-bg.com 
low-level protocolRS-232

ACS systems

Common name

Integrated hardware (name of devices)

Restrictions (monitoring, control, configuration)

Name in price-list

Information on manufacturer

Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT)

Connection interface (RS-232, TCP\IP)

Honewell N-1000 (pastN-1000Monitoring, control Honeywell Systems Group
Video and Access Control Solutions
Aston Fields Road
Whitehouse Industrial Estate
Runcorn
Cheshire
WA7 3DL
United Kingdom
Tel: +44 (0)8448 000 235
Fax: + 44 (0)01928 754050
Email: sales.video.uk@honeywell.com
www.security.honeywell.com
low-level protocolRS-232

Kronverk

Kronverk CM-TAuto configuration, monitoring, configuration, control "Access control systems" JSC
Serdobolskaya str., 65A
St. Petersburg
197342,
Tel.: +7 (812) 6000-282, 6000-283
E-mail: skd@kronwerk.ru
www.kronwerk.ru
SDKRS-232 - convertor - RS-485
Suprema

XPass

X-Station

BioEntry Plus

SecureIO

Monitoring, control Suprema 
17F Parkview Office Tower, Jeongja, Bundang, Seongnam, Gyeonggi, 463-863 Republic of Korea 
www.supremainc.com
SDKEthernet
KeyKing

TC312NT

TC322NT

TC344NT

TC348NT

TC388NT

Monitoring, configuration, control Add: 5F, Keyking Building, 12th, Shangwei Industrial No.1 Road, Zhangkengjing, Guanlan Town, Baoan District, Shenzhen, China, 518110. 
Tel: (+86)755-8829 9009 
Fax: (+86)755-8829 9004 
E-mail: info@keyking.net
low-level protocolRS-232, RS-485, Ethernet

Perimetral Security systems

Common name

Integrated hardware (name of devices)

Restrictions (monitoring, control, configuration)

Name in price-list

Information on manufacturer

Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT)

Connection interface (RS-232, TCP\IP)

FSGIPID Sterownik FSGMonitoring, control 

IPID Sp. z o.o.
ul. Zawiła 69
30-390 Kraków

Tel.: 123 977 613
Fax: 123 977 684
E-mail: biuro@ipid.pl
www.ipid.pl

BACnet protocolEthernet
Intrepid IIPM-II, MTP-II, AIM-8, AIM-16, ROM-8, ROM-16, MicroWave 330Monitoring, control Southwest Microwave, Inc.
9055 South McKemy Street
Tempe, Arizona 85284 USA
Telephone: (480) 783-0201
Fax: (480) 783-0401 
low-level protocolRS-232
FortezaZebra-30, Zebra-60, Zebra-100, ReliefMonitoring, auto configuration, configuration, control "OKHRANNAYA TECHNIKA" LLC
Tel.: +7 8412 655316
Fax: +7 8412 655316
E-mail: info@forteza-eu.com
www.FORTEZA-EU.com
low-level protocolRS-232
Optex

REDSCAN RLS-3060SH

RedBeam 
RBM-60QN/100QN/200QN IP

Monitoring, control 

OPTEX CO., LTD.
HeadquartersPublic Relations
Tel: +81-77-579-8000
Fax: +81-77-579-7190

low-level protocolEthernet

ACS/FSA combined systems

Common name

Integrated hardware (name of devices)

Restrictions (monitoring, control, configuration)

Name in price-list

Information on manufacturer

Way of integration (low-level protocol, communication server, SDK, SOFT-SOFT)

Connection interface (RS-232, TCP\IP)

Paradox

EVO48

ЕVO192

ACM12

Monitoring, configuration, control Paradox Security Systems 
Canada 
780 Industrial BoulevardSt-Eustache, QuebecCanada, J7R 5V3 
Tel: (450) 491-7444 
Fax: (450) 491-2313
low-level protocolRS-232, USB
FoxSec

FS9000

FS7002PX (MK)

FS7011PX (MK)

Monitoring, configuration, control 

FoxSec 
Tel: (372) 666-14-00 
E-mail: info@foxsec.eu

http://www.foxsec.eu/

low-level protocolEthernet
ApolloSDK v.2

AAN-100

AAN-32S

AAN-32N

AIM-2SL

AIM-4SL

AIO-168

ASA-72

Monitoring, configuration, controlSee detailed information in the Integration with Apollo SDK v.2 section

AAM Systems

Office address: Kraznokazarmennaya str., 13-402
Moscow
Post address: Kraznokazarmennaya str., 14
Moscow, 111250
Tel: +7 (495) 924-2227
Fax: +7 (495) 362-7262
E-mail: aam@aamsystems.ru
www.aamsystems.ru 

SDKRS-232, IP
HID

EDGE ER40; VertX: v1000, v100, v200, v300, v2000, EVO

Control reader HID Omnikey 5321

Monitoring, configuration, control 15370 Barranca Pkwy
Irvine, CA 92618-3106
Tel.: (949) 732-2000
Toll Free: (800) 237-7769
Fax: (949) 732-2120
http://www.hidglobal.com
SDKIP
       