GET
http://example.com:[port][/somecontext]/secure/video/action.do?version=4.7.8.0&sessionid=29101F1&cam.id=5&target=PTZ&targetid=1.1&command=RIGHT&login=XXX&password=YYY&speed=2
All parameters are mandatory.
The command parameter can have the following values:
- RIGHT
- UP
- LEFT
- DOWN
- ZOOM_IN
- ZOOM_OUT
speed – processing speed of command (from 0 to 10). Use low values (because of delays) to control via the network.
cam.id – camera id.
target - always PTZ
targetid –id of telemetry (sent in configuration).