The TELEMETRY_EXT object corresponds to the Keyboard system object.

The TELEMETRY_EXT object sends events presented in the table.  Procedure is started when the corresponding event appears.

Format of events procedure for the Keyboard object:

OnEvent("TELEMETRY_EXT","_id_","_event_")

Event

Description of event

Parameter

Description of parameter

Range of values

"KEY_PRESSED"

Key is pressed

param0<>

Code of pressed key

See  Руководство по установке и настройке компонентов охранной системы.

device<>

Device on which key is pressed

0 – Main keyboard AXIS T8312 ,

1 - AXIS T8313 keyboard

"KEY_RELEASED"

Key is released

param0<>

Code of released key

0..21 for AXIS T8312.

For BOSCH KBD-Digital, BOSCH KBD-Universal и Panasonic WV-CU950  see Руководство по установке и настройке компонентов охранной системы.

device<>

Device on which key is released

0 – Main keyboard AXIS T8312,

1 – Rotary switch AXIS T8313

"MOVED"

Position is changed

param0<>

Bias value

For wheel of JogDial rotary switch  -1.. 1; for wheel of frame-by-frame scrolling Shuttle -7..7

For keyboard Panasonic WV-CU950 JogDial  -1.. 1; Shuttle -6..6

device<>

Type of used control mechanism AXIS T8313

0 – wheel of rotary switch,

1 – wheel of frame-by-frame scrolling

Operator format to describe actions with the short message service is:

DoReact("TELEMETRY_EXT","_id_","_command_" [,"_parameters_"]);

List of commands and parameters for the TELEMETRY_EXT object is presented in the following table:

Command – command description

Parameters

Description

"DRAW_FIGURE" – draw figure on display of BOSCH KBD-Digital or BOSCH KBD-Universal telemetry panel

display<>

0x00 – main display, 0x01 –  status display

x1<>

Start coordinate on X axis (from 0 to 127 for main display, from 0 to 121 for status display)

y1<>

Start coordinate on Y axis (from 0 to 239 for main display, from 0 to 31 for status display)

x2<>

End coordinate on X axis (from 0 to 127 for main display, from 0 to 121 for status display)

y2<>

End coordinate on Y axis (from 0 to 239 for main display, from 0 to 31 for status display)

is_fill<>

0 – do not fill, 1 – fill

is_set_pixels<>

0 – remove figure from display, 1 – draw figure

figure<>

0 – line, 1 – rectangle

"PRINT_TEXT" – print text on display of BOSCH KBD-Digital or BOSCH KBD-Universal telemetry panel

display<>

0x00 –main display, 0x01 –  status display

x<>

Coordinate on X axis (from 0 to 127 for main display, from 0 to 121 for status display)

y<>

Coordinate on Y axis (from 0 to 239 for main display, from 0 to 31 for status display)

charset<>

Coding:

0 – Latin

1 – Cyrillic

2 – Central european

style<>

Style:

0 – Normal

1 – Semi-bold

 

text <>

Test message

 

"PRINT_TEXT" – print text on display of Panasonic WV-CU950 telemetry panel

y<>

0 – display text on first line

1 – display text on second line

text<>

 Entered text of line, maximum 20 symbols

flickering<>

Line consists of 6 symbols determining parameters of text flashing: d1 d2 d3 d4 d5 d6

d1 determines period of flashing :

0 – flashing disabled

1 - period 0.25 sec, symbol is changed by white space

2 - period 0.5 sec, symbol is changed by white space

3 - period 0.75 sec, symbol is changed by white space.

4 - period 1 sec, symbol is changed by white space.

5 - period 0.25 sec, symbol is changed by white space

6 - period 0.5 sec, symbol is changed by white space

7 - period 0.75 sec, symbol is changed by white space

8 - period 1 sec, symbol is changed by white space

d2: 1 – symbols from 1 to 4 are flashing, 0 – these symbols are not flashing.

d3: 1 – symbols from 5 to 8 are flashing, 0 – these symbols are not flashing.

d4: 1 – symbols from 9 to 12 are flashing, 0 – these symbols are not flashing.

d5: 1 – symbols from 13 to 16 are flashing, 0 – these symbols are not flashing.

d6: 1 – symbols from 17 to 20 are flashing, 0 – these symbols are not flashing.

" CLEAR_DISPLAY " – clear display of BOSCH KBD-Digital or BOSCH KBD-Universal telemetry panel.

Reaction without parameters for the Panasonic WV-CU950 telemetry panel.

display<>

0x00 – main display, 0x01 –  status display

"RELE_ON" – turn on the light on the AXIS T8312 keyboard or Panasonic WV-CU950panel

rele<>

Code of key with the light, 12..16 for AXIS T8312.

For Panasonic WV-CU950 see Руководство по установке и настройке компонентов охранной системы, section Особенности настройки и работы с пультом управления телеметрией Panasonic WV-CU950.

"RELE_OFF" – turn off the light on the AXIS T8312 keyboard or Panasonic WV-CU950 panel

rele<>

Code of key with the light, 12..16

"RESET" – reset of Panasonic WV-CU950 panel

type<>

0 – instant reset

1 – reset after 100 ms.

2– reset after 200 ms.

3– reset after 500 ms.

4– reset after  1 s.

"SET_ALARM" – set type of alarm signal of the Panasonic WV-CU950 panel

audio_alarm<>

0 – sound OFF

1 – simple single alarm signal

2 – simple double alarm signal

3 – simple triple alarm signal

4 – single alarm signal lasting 0.1 sec.

5 – single alarm signal lasting 0.2 sec.

6 - single alarm signal lasting 0.3 sec.

7 - single alarm signal lasting 1 sec.

8 – simple single tone

9 – simple double tone

A– simple triple tone

B– single signal lasting 0.1 sec

C– single signal lasting 0.2 sec

D– single signal lasting 0.3 sec

E– single signal lasting 1 sec

F – alarm signal

 

Example of using events and reactions of the TELEMETRY_EXT object:

  1. Turn on the light and arm camera 2 after pressing the key 15 on the AXIS T8312 keyboard.

    OnEvent ("TELEMETRY_EXT","1","KEY_PRESSED")
    {
        if (strequal(param0, "15")){
            DoReact("TELEMETRY_EXT","1","RELE_ON","rele<15>");
            DoReact("CAM","2","ARM");
        }
    }