The Event viewer object represents an interface box showing text information about the events initiated by the distributed surveillance system.

The settings panel of the Event viewer object is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Event viewer object.

Parameter

Method for setting the parameter

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Event viewer object in the digital distributed video surveillance system.

Sequence of numbers

-

From 1 and above.

Depends on the number of Event Viewer objects in the digital distributed video surveillance system.

2

Name*

Type-in the value in the field

Sets the name of the Event viewer object in the digital distributed video surveillance system.

Latin, Cyrillic and service characters

Event Viewer

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Checkbox

Sets the status of the Event viewer object (enabled or disabled) in the digital distributed video surveillance system.

Boolean type

No

Yes – the Event viewer is disabled and is not in use.

No – the Event viewer is enabled and is in use.

4

Screen

Select in the list

Specifies the parent Display object  of the digital distributed video surveillance system, to which the given Event viewer object refers.

Names of Display object s registered in the system

Name of the parent Display object .

Depends on the number of Display object s in the digital distributed video surveillance system.

The Settings group

 

 

 

5

 

X

Type-in the value in the field

 

Sets the coordinate in the X horizontal axis for the upper left corner of the window of the Event viewer interface object on the screen.

% of the screen width

Not set

From 0 to M*100, where M is the number of monitors installed.

Y

Type-in the value in the field

Sets the coordinate in the Y vertical axis for the upper left corner of the window of the Event viewer interface object on the screen.

% of the screen height

Not set

From 0 to M*100, where M is the number of monitors installed.

 

 

6

W

Type-in the value in the field

Sets the window width of the Event viewer interface object.

% of the screen width

Not set

From 0 to M*100, where M is the number of monitors installed.

H

Type-in the value in the field

Sets the window height of the Event viewer interface object.

% of the screen width

Not set

From 0 to M*100, where M is the number of monitors installed.

7

Monitor

Is selected in the list

The number of monitor in OS for which coordinates are specifying

Numbers of monitors

1

1-16

8

Display days

Type-in the value in the field

Sets the number of days to keep the event recording archive in the Intellect database.

Days

1

More than 1

9

View

Select in the list

Sets the events for displaying in the window of the Event Viewer.

-

All events

All events – all events are displayed in the Event Viewer window

Last event – one last event is displayed in the Event Viewer window

All last events – all last events are displayed for all selected objects

10

Display video

Checkbox

Allows Operator viewing archive footage of the events, initiated by the Event Viewer as Record to disk using the Event viewer box.

Boolean type

No

Yes – Operator is allowed viewing the archive footage using the Event Viewer window.

No – Operator is not allowed viewing the archive footage using the Event viewer window.

11

Display object on map

Checkbox

Allows Operator viewing objects, displayed in the Event viewer window, on the map.

 

Boolean type

No

Yes - Operator is allowed viewing the objects, displayed in the Event Viewer window, on the map.

No - Operator is not allowed viewing the objects, displayed in the Event Viewer window, on the map.

12

Display report

Checkbox

Allows Operator creating a printed form of the report and printing out the information about all events registered by the Event viewer within the pre-set period of time.

 

Boolean type

No

Yes - Operator is allowed creating a printed form of the report and printing out the information about all events registered by the Event Viewer within the pre-set period of time.

No - Operator is not allowed creating a printed form of the report and printing out the information about all events registered by the Event Viewer within the pre-set period of time.

13

Load protocol

Checkbox

Defines, whether or not the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the launch of Intellect™ software.

Boolean type

No

Yes - the latest 1000 events registered by the Event viewer with the latest system start, should be downloaded with the launch of Intellect™ software.

No - the latest 1000 events registered by the Event viewer with the latest system start, should not be downloaded with the launch of Intellect™ software.

The Objects group

14

Type

Select in the list

Sets the types of objects to be displayed in the Event viewer.

NOTE. If the field is empty, the Event viewer displays all events for all objects in the system.

Types of objects registered in the system.

Not set

Depends on the number of types of objects created in the digital distributed video surveillance system.

15

Number

Select in the list

Sets the identification number of the device.

NOTE. If the field is empty, the Event viewer displays all events for all objects of the selected type.

Sequence of numbers

Not set

Depends on the number of created devices of the selected  type in the digital distributed video surveillance system.

16

Name

Automatically

Specifes the name of the device selected in item 14.

 

Name of the  objects of the selected type registered in the system

Name of specified system object

Depends on the number of devices of the selected type in the digital distributed video surveillance system.

17

Event

Select in the list

Specifies which event coming from selected devices is to be logged.

NOTE. If the field is empty, the Event viewer displays all events coming from specified devices.

Names of event types for selected type of devices.

Not set

Depends on the type of device.

The Areas group

18

Name

Select in the list

Sets the region where the objects to log the events from are located.

Name of the region registered by the system.

Not set

Depends on the number of Region objects created in the digital distributed video surveillance system.

The Advanced settings group

19

Color of alarm messages

Select in the list or on the Select color panel.

Sets the color of the alarm messages in the Event viewer window.

RGB, CMY or HSL.

Red

Corresponds to the standard range of the selected color system.

20

Color of information messages

Select in the list or on the Select color panel.

Sets the color of the information messages in the Event viewer window.

RGB, CMY or HSL.

Blue

Corresponds to the standard range of the selected color system.

21

Duration of blinking, sec:

Type-in the value in the field

Sets the duration of alarm message blinking in the Event viewer window.

C

Not set

More than 0

22

Font:<current font>

 

Click the button

Sets the font of information messages in the Event viewer window

Standard Font Windows dialog box

Depends on OS settings

-

*The name of the element is not displayed in the settings panel of the given object.