Events are processed in the Current events tab of the Operator protocol.
Events registered by alarm objects with no type assigned and events escalated from a lower level are displayed in the Current events tab. Every event is in a form of information panel with control elements.
To assign a type to the event, click one of the buttons on the information panel of the corresponding event. After the type is assigned to the event, it is removed from the Current event tab.
Note.
If the time of waiting the respond from operator (specified in the settings of the Operator protocol object) (see Intellect software package. Administrator guide) is exceeded, then the event is removed from the Current events tab and the Non-processed type is assigned.
Note.
If all non-processed events are to be assigned with the type of selected event, then set the Apply to all checkbox.
To zoom in the alarm frame, repeatedly click on it with the left mouse button. In 20 seconds after zooming in the frame gets its initial size.
To view or export the video of the event, click the Enter archive button on the information panel of the corresponding event.
The archive of video recordings opens in the Video surveillance monitor and the current position of playback will be set at the position corresponding to the beginning of video recording.
To view the object from which the event comes on the interactive Map, click Find on Map. As a result the required layer of the interactive Map is displayed.