Go to documentation repository
Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.
Previous page Next page
To set the event viewer parameters, do the following:
- Go to the Main tab on the settings panel of the Event viewer object (1).
If it is necessary to display only one latest event or all latest events in Event Viewer interface box, select One latest or All events in the View events: list (2).
Note.
If All events item is selected and the event is repeated for the object, there is time changing of present event recording and a new recording line is not created.Note.
By default all events are displayed in the Event Viewer interface box.- In the View days field set the number of days to display the events in the Event viewer interface box (3).
- Set the Show video checkbox to enable viewing the video recordings from the Event viewer interface box (4). Viewing the events of the Record to disk type of the Camera objects is only possible.
- Set the Show object on the map checkbox to enable viewing the logged events on the map (5).
- Set the Show report checkbox to enable creating a printed report about events in the Events viewer interface box for a specified time period (6).
If the last 1000 logged events are to be displayed in the Event Viewer interface box, then set the Load protocol checkbox (7).
Note.
When the Load protocol checkbox is set, the events of those objects that have been deleted without giving a source (the name of a deleted object is not displayed) can be displayed. Such operation of the Event Viewer allows the extra control over system objects.Note.
A thousand of last events for each object or each object type is loaded when the Load protocol checkbox is set if the filter of Event log is configured for displaying events from several objects or several object types.
For example, if the Event log is receiving events from Camera 1 object and from all Macros objects, a thousand of events from Camera 1 object and a thousand of events from Macros objects will be loaded.- Click the Apply button to save all the changes.
Event viewer parameters are now set.
Overview
Content Tools