Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
Previous page Next page
The Detection zone object is used to register and configure intelligent video detectors. The settings panel of the Detection zone object is shown in figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Detection zone object.
№ | Parameter | Method for setting the parameter value | Parameter description | Symbols used | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Detection zone object in the digital distributed video surveillance system. | Sequence of numbers | - | Depends on the number of Detection zone objects in the digital distributed video surveillance system. |
2 | Name* | Enter the value in the field | Defines the name of the Detection zone object in the digital distributed video surveillance system. | Latin, Cyrillic letters and service characters | Detection zone | A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. Number of symbols – from 1 to 60. |
3 | Disable | Is identified by the check mark | Defines the condition of the Detection zone object (enabled or disabled) in the digital distributed video surveillance system. | Boolean type | Not available | Yes – the Detection zone is disabled and is not in use No – the Detection zone object is enabled and is in use. |
4 | Camera | Is selected from the list | Defines the parent Camera object of the digital distributed video surveillance system, to which the given Detection zone object refers. | Name of the Camera objects registered in the system | Name of the parent Camera object. | Depends on the number of Camera objects in the digital distributed video surveillance system. |
5 | Alarmed | Is identified by the check mark | Starts automated recording of the video signal from the camera with the alarm received from the selected detector. | Boolean type | Not available | Yes – automated recording of the video signal with the alarm received from the selected detector is in progress.
No – automated recording of the video signal with the alarm received from the selected detector is not in progress. |
6 | Always armed | Is identified by the check mark. | Defines the condition of the selected detector as Always armed. | Boolean type | Not available | Yes – the detector should always be armed.
No – the operator may disarm the detector. |
Direction Group | ||||||
7 | Direction of search* | Press the arrow buttons. | Defines the direction of search for the motion detector. | 8 possible directions to follow an object within the frame. | Pressed: up, down, to the left, to the right Pulled out: up and to the left, up and to the right, down and to the left, down and to the right. | Up, down, to the left, to the right, up and to the left, up and to the right, down and to the left, down and to the right. |
Out of the groups | ||||||
8 | Detector | Is selected from the list | Is used to define the type of the detector in use. | List of the detectors in the system. | Motions | Motion Focus Stability Background change Blind Cover Abandoned objects Infrared |
9 | Show | Is identified by the check mark | Defines the frame border in the observed scene. This parameter is active only with the following detectors selected from the Detector list: motion, abandoned objects, infrared. | Boolean type | Yes. | Yes – the object border is displayed in the observed scene. No – the object border is not displayed in the observed scene.
|
10 | Sensitivity | Set the slide in the required position. | Defines the cognominal parameter of the selected detector settings. Depends on the type of detector selected. | - | Average | - |
11 | Contrast | Set the slide in the required position. | Defines the cognominal parameter of the selected detector settings. Depends on the type of detector selected. Is not applicable for all detector types. | - | Average | - |
12 | Filtration | Set the slide in the required position. | Defines the cognominal parameter of the selected detector settings. Depends on the type of detector selected. Is not applicable for all detector types. | - | Minimal | - |
13 | Size | Set the slide in the required position. | Defines the cognominal parameter of the selected detector settings. Depends on the type of detector selected. Is not applicable for all detector types. | - | Average | - |
14 | Set delimitation lines | Is not used | - | - | - | - |
*Name of the element is not displayed in the settings panel of the given object.