Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

The Failover object is used to ensure operation of distributed system in the failover mode.  

The settings panel of the Failover object is shown in figure.

Description of setting parameters relevant to elements on the settings panel of the Failover object is given in table.

 

Parameter

 

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Monitor PC

Select in the list

Sets the name of the Server the state of which is to be under control

Names of the Computer objects registered in the system

-

Depends on the number of the Computer objects registered in the system

2

Expect reconnection (sec)

Type-in the value in the field

Sets the time period (in seconds) at the end of which configuration will be transferred to backup Server

Sequence of numbers

-

From 0 to 65535

3Time left __ days

Automatically

Shows the period of time (in days) remaining for restoring the configuration from backup Server and restoring the license

Days

0.00

From 0.00 to 60.00

4

Type

Select in the list

Sets the object type in Server configuration that is to be transferred to backup Server in case of connection failure 

Types of objects registered on the base of the main Server

-

Depends on the configuration created on the base of the main Server  

5

Number

Select in the list

Sets the ID of object of selected type that is to be transferred to backup Server in case of connection failure 

ID of objects of selected type that are in Server configuration

-

Depends on the number of objects of selected type in the configuration of main Server

6

Name

Automatically

Sets the object name that is to be transferred to backup Server in case of connection failure 

Names of objects of selected type that are in Server configuration

-

Depends on the configuration created on the base of the main Server  

7

Range

Click the button

Opens the dialog box for integrated selection of tracking objects

-

-

-

  • No labels