It is possible to enable or disable (permanently or on time from 1 to 255 seconds) one from eight controlled exits when some event is received if the reaction mode is activated in the system. Some executive or warning device can be connected to this exit.

To configure reactions, do the following:

  1. Go to the Gate parking access point object’s settings panel and click the Reaction on events button.
  2. The list of events for which reactions can be configured is presented in the relevant column. To set reaction on the event, do the following:
  3. From the corresponding list select reader on which the event is to be performed (1).

    Note.

    Reader 1 – reader on entry, Reader 2 – reader on exit.
  4. Select the performed action (2).
  5. Set the action performing time in the range from 1 to 255 seconds in the Time column (3).
  6. Select the exit which is to be enabled or disabled in the Executor column (4).
  7. Click the Apply button (5).
  8. Click the Apply button on the Gate Parking access point object’s settings panel.
  9. Forward configuration to the controller (see the Managing the configuration of a Gate controller section).

Configuring of reactions is completed.