The Fire detection module can be configured on the settings panel of the Fire detection object created on the basis of the Camera object on the Hardware tab of the System settings dialog window.

The Fire detection module is configured as follows:

  1. Go to the Fire detection object's control panel.
  2. In the Skip repeated recognitions, sec field enter the time period in seconds during which the system must ignore repeated messages about ignition (1). For example, if 5 seconds is set for the Distance in seconds between processed frames parameter, and there is a fire on the image during a longer period of time then set Skip repeated recognitions, sec to a higher value (for example, 10 seconds) to avoid receiving messages of ignition from the detector every 5 seconds.
  3. In the Detection sensitivity: 0..100: field enter the sensitivity of detection – integer value from 0 to 100 (2). This parameter has an impact on sufficient probability of fire recognition for alarm. For example, if sensitivity is 0, than frame on which fire is recognizied with certainty more than 95% will be alarming. If sensitivity is 100, than frame with 50% certainty of fire recognition will be alarming.
  4. In the Distance in seconds between processed frames: field enter the time period in seconds separating frames used by algorithm for fire analysis (3). This parameter has an impact on processor capacity: the less the parameter, the more capacity. Also it has an impact on operation speed of algorithm: the less distance between frames. the faster required number of frames will be collected for decision and alarm, if it's required.
  5. In the Number of frames for analysis and output: field enter minimum number of frames for detection analysis before alarm generating (4). The more the value, the more certain the result of detection operation. At the same time, if value is too large, the short-time fire can be missed.

    Note.

    Multiplication of Distance in seconds between processed frames * Number of frames for analysis and output parameters characterizes time period (in seconds) at the end of which after fire alarm will be triggered.

  6. Specify the detection surveillance area on the video image:
    1. Click the Setup button. The Detection settings window will open.
    2. Click the Stop video button to capture the video image (1).
    3. Click the Area of interest button (2).
    4. Specify area on which smoke recognition will be detected (3).
    5. Click the OK button (4).
  7. Click the Apply button (6).

Configuring the Fire detection module is complete. 