When changing the ddi file events, reactions, etc. can be added, modified or deleted.
To reduce database load modify the intellect.ddi file as follows:
- Open the intellect.ddi file in the ddi.exe utility.
- Select the CAM object.
- Go to the Events tab.
- Set the Do not record and Do not send to the network checkboxes checked for the MD_START (Alarm) and MD_STOP (Alarm end) events.
Save the file.
Update the database using the idb.exe utility (the Update database button, see Interface elements of the idb.exe window).
When these actions are performed the events from the main motion detection tool are not recorded and sent to other cores. This reduces the database load.
Important!
When updating Intellect the modified intellect.ddi file is replaced with the file by default.
Чтобы избежать замены файла intellect.ddi, необходимо на шаге 5 сохранить файл с другим именем, например, "intellect_1.ddi". Таким образом, в каталоге Languages будет храниться 2 файла внешних настроек: исходный и модифицированный. Утилита idb.exe при обновлении будет загружать их в алфавитном порядке. В результате такой сортировки файл intellect_1.ddi будет загружен последним, и именно его параметры будут приняты при обновлении базы данных.
При установке новой версии ПК Интеллект поверх старой, файл intellect_1.ddi не будет затронут программой установки, и изменения не будут потеряны.
Important!
When deleting Intellect without saving the configuration the entire Intellect catalog (including modified files) is deleted. In this case the modified files are to be manually backed up, e.g. to C:\Temp, а после повторной установки скопировать их в каталог <Директория установки ПК Интеллект>\Languages\ru.