Go to documentation repository
Previous page Next page
Advanced settings for the HikVision controller are available via the HikVision 26X or HikVision 28X object configuration panel. You can create these objects under a parent Computer object using the Settings dialog box on the Hardware tab, or it can be created automatically (see ). As an example of HikVision controller advanced settings, let's consider a HikVision 26X controller.
To perform an advanced setup of a HikVision controller, do the following:
- Go to the Others tab (1) on the Hikvision 26X object configuration panel.
- Check the APB Enabled box (2) to enable anti-pass-back monitoring.
- From the APB Reader (3) drop-down list, select the starting reader for anti pass-back monitoring.
- select the starting reader for anti pass-back monitoring.
Advanced setup of the HikVision controller is now complete.
Overview
Content Tools