Go to documentation repository
Previous page Next page
The ZK Teco door for the controller C3-100 is configured on the settings panel of the AC ZK Door C3-100 object which is created on the basis of the AC ZK Controller C3-100 object on the Hardware tab of the System settings dialog window.
Note.
Available number of doors is automatically created under the corresponding controller, i.e. one door is created under the controller C3-100, two doors under the controller C3-200 and four doors under the controller C3-400.
To configure the ZK Teco door, do the following:
- Go to the settings panel of the AC ZK Door C3-100 object.
- From the Number: drop-down list select the number of the door (1).
- From the Type: drop-down list select the type of verification (2).
- In the Emergency: field enter the password for door open (3).
- In the Duress: field enter the password for door open and triggering the alarm event (4).
From the Type: drop-down list select the type of door sensor (5).
Note
The door sensor type affects the way pass events are generated.
Disable: the event about the user's pass is generated automatically, as soon as the user has been identified.
- Normal open/Normal close: the event about the user's pass is generated when the user actually passes (by closing or opening the reed switch of the door, respectively).
- From the Door hold alarm timeout: drop-down list select the time interval during which door is opened (6).
- Set the Close and lock checkbox to lock the door after its closing (7).
- From the Door relay: drop-down list select the time interval of opening the door after the card presenting (8). Select the Close value for permanent closing the door. Select the Open value for permanent opening the door.
- From the Punch: drop-down list select the time interval of card presenting (9).
Set The first card opens door checkbox to open the door using the first card (10).
Note.
Access level of first card for the door opening is configured in the panel of user editing in the Access Manager interface module. In the Level in first card mode field specify the corresponding access level.
- Set the Enable checkbox to allow using of multicard combinations (11).
- From the drop-down list in the Multicard column select the required multicard combination (configuring of multicard combinations is given in the section, 12).
- From the Valid: drop-down list select the time zone in which the door is active (13). If the Never value is selected, the door will not operate.
From the Keep open: drop-down list select the time zone in which the door will be normally opened (14).
Note.
The door will be opened in not more than 1 minute after starting the specified time zone.
- From the Region In: drop-down list select the Region object located in the site of exit through the door (15).
- From the Region Out: drop-down list select the Region object located in the site of entry through the door (16).
- Click the Apply button (17).
To send the specified settings to controller click the Send configuration button on the settings panel of the AC ZK Controller C3-100 object.
Configuring of the C3-100 door is completed.
Note.
Settings for doors of controllers C3-200 and C3-400 are the same.