Go to documentation repository
Previous page Next page
Purpose of integration the Intellect software package with FSA/ACS/PSS device
- Provide user interface on the same software in the context of different security equipment subsystems.
- Configure cause-and-effect connection between different subsystems (video surveillance, FSA, ACS, audio registration, etc.).
- Use network capability of the software.
- Joint marketing promotion of integrated solution by software and hardware manufacturers.
Ways of integration:
- Low-level protocol. The system developer presented events, reactions and equipment connection commands as the byte set, so the equipment can be directly connected to Intellect.
SDK – Software Development Kit. The system developer presented SDK, so the equipment can be directly connected to Intellect.
- Communication server (Program-driver). The system developer presented own driver (program layer between ITV|AxxonSoft software and hardware in which events, reactions, configuration commands and state request are built in) in order to connect the equipment. Install the third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. COM-server and OPC-server are examples of such programs.
- SOFT-SOFT. The system developer enabled using its commands in Intellect and vice versa in order to connect the equipment. Install the full version of third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. to access the event log.
Universal protocol integration: OPC, SNMP and BACnet. OPC and BACnet are industry standards. The system developer makes OPS-server and BACnet-server implementation for its devices and sends data over OPC or BACnet protocols. Intellect is the client for such servers and it gets data (events, reactions, configuration commands, etc.). SNMP is a network protocol used to monitor some devices. The list of some hardware connected to Intellect over universal protocols is specified in the Systems connected by universal protocols section.
- Drivers Pack. An equipment was integrated using one of the above methods via Axxon Drivers Pack. When this method is employed, the Drivers Pack is to be installed together with ACFA-Intellect to work with the equipment.
Integrated hardware
Note
Documentation is available in English only for integration modules names of which are marked "*" in the table as these modules are not included in the Russian version of ACFA Intellect installation package.
Note
Fire&Security Alarm (FSA) systems
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA-Intellect version |
POLON ALPHA
| Polon4500, Polon4900, TSR, ROP, EKS, EWK, SAL, UCS | Monitoring, control | INTELLECT Alarm Service (Polon), per panel | Polon-Alfa Spółka z ograniczoną odpowiedzialnością Sp.k. http://www.polon-alfa.pl/en | low-level protocol | RS-232 | - |
NCG-9 | NCG-9, NCG-13 | Monitoring, configuration, control | INTELLECT Alarm Service (NCG9) | ANDY Complex "ANDY", Karlovsko Shosse Blvd., 4003 Plovdiv, phone: 032/904 000 fax: 032/904 004 http://www.andi-bg.com/ | low-level protocol | Ethernet | - |
Satel | Integra 32 / Integra 64 / Integra 64 + / Integra 128+ / Integra 256+ | Monitoring | INTELLECT Alarm Service (Satel), per panel | SATEL www.satel.pl | low-level protocol | RS-232 | 6.3 |
Aritech | FP2000 | Monitoring, control | INTELLECT Alarm Service (Aritech), per panel | Aritech | low-level protocol | RS-232 | 5.3 |
UniPOS | IFS – 5000, 7000, 7203-O, 7203-IO, 7203-R, 7203-OC FS 4000 | Monitoring, configuration, control | INTELLECT Alarm Service (UniPOS Conventional Series), per line INTELLECT Alarm Service (UniPOS Addressable Series), per panel | UniPOS | low-level protocol | RS-232 | - |
SALTO | CU50ENSVN, GateWay, Encoder | Monitoring, configuration, control | INTELLECT SALTO integration module | Salto www.saltosystems.com | SOFT-SOFT | Ethernet | - |
TELSAP | Telsap 2100 | Monitoring, configuration, control | INTELLECT Alarm Service (Polon-Alfa Telsap), per panel | Polon-Alfa Spółka z ograniczoną odpowiedzialnością Sp.k. http://www.polon-alfa.pl/en | low-level protocol | RS-232 | - |
Siemens Cerberus ECO | FC1840-A3 panel, FDT181(heat) and FDO181(smoke) sensors; input module FDCI181-2 and I/O module FDCIO181-2; short-cirquit isolator FDCL181. | Monitoring, control | INTELLECT Alarm Service (Siemens Cerberus ECO), per panel | Siemens | low-level protocol | RS-232 | 5.2 |
DSC | DSC PC-1864 | Monitoring, control | INTELLECT Alarm Service (DSC), per panel | 3301 Langstaff Road | low-level protocol | RS-232 | 6.1 |
Nedap retail | !Sense | Monitoring, control | INTELLECT Alarm Service (Nedap Retail), per RFID reader | Global headquarters Nedap Retail Parallelweg 2d 7141 DC Groenlo The Netherlands T +31 (0) 544 471555 | SDK | Ethernet | 6.3 |
Access Control Systems (ACS)
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA-Intellect version |
Castle | Pro, Pro4, RS, ES, EP, EP2, EP4 | Monitoring, configuration, control | Intellect Access Control Service (Castle), per IP | Agregator http://bg.agrg.eu | communication server | USB-RS485, Ethernet | - |
Honeywell N-1000 (past Northern Computers) | N-1000 | Monitoring, control | INTELLECT Access Control Service (Honeywell N-1000-IV), per COMort | Honeywell Systems Group Video and Access Control Solutions www.security.honeywell.com | low-level protocol | RS-232 | - |
Suprema | XPass X-Station BioEntry Plus SecureIO | Monitoring, configuration, control | Intellect Access Control Service (Suprema), per controller | Suprema www.supremainc.com | SDK | Ethernet | - |
KeyKing | TC312NT TC322NT TC344NT TC348NT TC388NT | Monitoring, configuration, control | INTELLECT Access Control Service (KeyKing), per reader | KEYKING | low-level protocol | RS-232, RS-485, Ethernet | - |
Paxton | Net2 nano Net2 plus Net2 classic Net2 I/O Board | Monitoring, configuration, control | Intellect Access Control Service (PAXTON), per Controller | Paxton | SOFT-SOFT | RS-232, USB, Ethernet | - |
Pelco | eIDC Intelli-M | Monitoring, configuration, control | INTELLECT Access Control Service (Infinias), per IP | Infinias http://infinias.com/ | low-level protocol | Ethernet | - |
Impro | Impro (ECII) Ethernet Controller Impro (iTRT) Intelligent Twin Reader Terminal Impro (iTT) Intelligent Twin Antenna Terminal Impro (MDTA) Multi-discipline Time Attendance Impro I16 16 Channel Input Terminal Impro O16 16 Channel Output Terminal | Monitoring | INTELLECT Access Control and Fire Alarm Service (Impro), per terminal | Impro Technologies | SOFT-SOFT | Ethernet, RS485 | 5.3 |
Anson DB | Andy ME12 | Monitoring | INTELLECT Access Control Service (Anson), per system | INDI | low-level protocol | Ethernet | - |
Velocity Hirsch | M8N, M2N, M16 | Monitoring | INTELLECT Access Control Service (HIRSCH Velocity), per reader | Identiv | SOFT-SOFT | Ethernet | 5.4 |
Nitgen | NAC 2500 | Monitoring, configuration, control | INTELLECT Access Control Service (Nitgen), per reader | Nitgen Co., Ltd. Fax : +82-2-6488-3096 Sales/Marketing : sales1@nitgen.com | SDK | Ethernet | 6.0 |
ZK Teco | C3-100, C3-200, C3-400 | Monitoring, configuration, control | INTELLECT Access Control Service (ZKAccess), per door | ZKTeco Phone: +86 755-33985019 | SDK | Ethernet, RS485 | 6.2 |
Unicard U700 | U700 controller | Monitoring, configuration, control | INTELLECT Access Control Service (UNICARD), per access control point | Unicard SA Phone: 12 39 89 900 | low-level protocol | Ethernet | 6.2 |
Soyal | AR-721E, AR-716E-IO, AR-723(H), AR-737(H-R), AR-721(H), AR-725(H-M), AR-725(E-V2-M), AR-727(H) | Monitoring, configuration, control | INTELLECT Accsess Сontrol Service (Soyal), per controller or INTELLECT Access Control Service (Soyal), per reader | Soyal Technology CO., LTD Tel: +886-2-2691-8031 Fax: +886-2-2691-8093 http://soyal.com/ | low-level protocol | RS-232, RS-485, Ethernet | - |
Suprema 2 | BioStation 2 BioEntry W FaceStation Any device with SDK v.2 support | Monitoring, control | INTELLECT Access Control Service "Suprema 2", per reader | Suprema www.supremainc.com | SDK | Ethernet | 6.5 |
HikVision | Controllers: DS-K2604, DS-K2804 Readers: | Monitoring, configuration, control | INTELLECT Accsess Сontrol Service (HikVision), per reader | Hikvision USA | SDK | Ethernet, RS-485 | 6.5 |
Perimetral Intrusion Detection systems (PIDs)
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA-Intellect version |
FSG | IPID Sterownik FSG | Monitoring, control | INTELLECT IPID Sterownik FSG Service, per device | IPID Sp. z o.o. | BACnet protocol | Ethernet | 5.4 |
Forteza | Forteza-Adapter, Forteza-Controller, FM Series, Forteza series, Security Light LED series, MIR-M series, RELIEF series, MIR-B series | Monitoring, auto configuration, configuration, control | INTELLECT perimeter security system Integration with "Forteza" | "OKHRANNAYA TECHNIKA" LLC www.FORTEZA-EU.com | low-level protocol | RS-232 | - |
Optex | REDSCAN RLS-3060SH RedBeam RBM-60QN/100QN/200QN IP | Monitoring, control | INTELLECT Burglar Alarm Service (OPTEX), per device | OPTEX CO., LTD. | low-level protocol | Ethernet | - |
Intrepid II | PM-II, MTP-II, AIM-8, AIM-16, ROM-8, ROM-16, MicroWave 330 | Monitoring, control | INTELLECT Intruder Alarm Integration with "Intrepid MicroPoint II", "Intrepid MicroTrack II" | Southwest Microwave, Inc. 9055 South McKemy Street Tempe, Arizona 85284 USA Telephone: (480) 783-0201 Fax: (480) 783-0401 | low-level protocol | RS-232 | - |
FFT | Foss locator Aura SR Aura LR Secure point 8 Channels | Monitoring, control | INTELLECT Alarm Monitoring Service (FFT Cams), per sensor | Future Fibre Technologies Limited | SOFT-SOFT | Ethernet | 6.0 |
ADPRO PRO E-Series | All ADPRO PRO E-series sensors | Monitoring | INTELLECT Alarm Service (Xtralis), per panel | Xtralis | low-level protocol | RS-232 | 6.2 |
ACS/FSA combined systems
Common name | Integrated hardware (name of devices) | Restrictions (monitoring, control, configuration) | Name in price-list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA-Intellect version |
Paradox | EVO48 ЕVO192 ACM12 | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Paradox), per COM port | Paradox Security Systems http://www.paradox.com/ | low-level protocol | RS-232, USB | 5.3 |
FoxSec | FS9000 FS7002PX (MK) FS7011PX (MK) | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Foxsec), per controller | FoxSec | low-level protocol | Ethernet | 5.2 |
ApolloSDK v.2 | AAN-100 AAN-32S AAN-32N AIM-2SL AIM-4SL AIO-168 ASA-72 | Monitoring, configuration, control | See detailed information in the Integration with Apollo SDK v.2 section | AAM Systems Office address: Kraznokazarmennaya str., 13-402 | SDK | RS-232, Ethernet | - |
HID | EDGE ER40; VertX: v1000, v100, v200, v300, v2000, EVO | Monitoring, configuration, control | INTELLECT Access Control Service (HID VertX/Edge), per reader | HID Glogal http://www.hidglobal.com | SDK | Ethernet | - |
Honeywell Galaxy Dimension | Galaxy GD-48 Galaxy GD-96 Galaxy GD-264 Galaxy GD-520 DCM MAX4 | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Honeywell Galaxy Dimension), per COM port | Honeywell Systems Group | low-level protocol | RS-232, Ethernet | - |
Control readers
General | Integrated hardware (name of devices) | Name in price-list |
---|---|---|
Documentation | HID Omnikey 5321 Biosmart FS80 Suprema BioMini | Intellect software package - Control reader for visitor management system An unlimited number of control readers is also included in the INTELLECT Visitor Management System license |
Systems connected by universal protocols
Name | Functionality in the Intellect software package | Name in price-list | Universal protocol |
---|---|---|---|
Bosch (all devices works by the same OPC-server) | Monitoring, control (full list of supported states you can find here) | INTELLECT OPC Wrapper module, per OPC computer | OPC |
FSA SIEMENS Cerberus-PRO |
| INTELLECT OPC Wrapper module, per OPC computer | OPC |
ACS Gallagher 6000 |
| INTELLECT OPC Wrapper module, per OPC computer | OPC |
Schrack Seconet (OPC server by TIGER-SOFT http://www.tiger-soft.com.pl) |
| INTELLECT OPC Wrapper module, per OPC computer | OPC |
Honeywell Esser (OPC server by TIGER-SOFT http://www.tiger-soft.com.pl) | Monitoring:
Control:
| INTELLECT OPC Wrapper module, per OPC computer | OPC |
Sterownik FSG |
| INTELLECT BACnet Wrapper Module, per device | BACnet |
AVTECH - Room Alert 24E- Alarm Switch | Monitoring of the following events:
| INTELLECT SNMP Wrapper module, per channel | SNMP |
MOXA Remote I/O Series cards of any type: Ethernet I/O, RS-485 I/O or Modular I/O (for the list of all cards which can be connected by the SNMP please refer here) |
| INTELLECT SNMP Wrapper module, per channel | SNMP |
NAG SNR-ERD | Receiving status and events from controller elements, for example, temperature sensors, relay status (on, off) | INTELLECT SNMP Wrapper module, per channel | SNMP |
TFortis | Device status poll | INTELLECT SNMP Wrapper module, per channel | SNMP |
Note