Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Electrical and technical specifications of SL USBIO (4x4, 16x8 and 24x4) card  Appendix 6. Maximum number of presets for IP devices Next page


When connecting the AGRG-IO-16/8-WD-DS sensor-relay cards, the electrical and technical specifications shown in the table below should be considered.

ParameterSpecification
Galvanic isolation on inputs/outputs

3750 V

Inputs

Quantity - 16

Type - current loop

Galvanic isolation - Yes

Maximum voltage - 60 V

Rated voltage - 12 V

Maximum current - 60 mA

Outputs

Quantity - 8

Type - open collector

Galvanic isolation - Yes

Maximum voltage - 300 V

Maximum current - 150 mA

Minimum pick-up voltage - 1.0 V

Minimum pick-up current - 5 mA

Reset Timer (Watchdog)Customizable
Ping interval of all alarm inputs100 ms for all contacts. Customizable
PC connection interfaceUSB 2.0, up to 5 meters
Power supply500 mA consumption from USB port