Documentation for Detector Pack 2.7. Documentation for other versions of Detector Pack is available too.
Previous page Next page
Attention!
The Neurotracker software module works only in Intellect 4.11.0 and higher version.
The Neurotracker software module is configured on the Neurotracker object settings panel. This object is created under the Camera object on the Hardware tab of the System settings window.
The Neurotracker software module is configured as follows:
- Go to the Neurotracker object settings panel.
- Set the Show objects on image checkbox (1) if it is necessary to highlight the detected object with a frame in the Monitor object interface window.
- Click the button (2), and in the standard Windows window that opens, select the neural network file with the tracking model.
- In the Sensitivity, % field (3), specify the neurotracker sensitivity — an integer value within the range from 0 to 100.
- In the Frame rate limit field (4), specify the maximum number of frames per second that should be analyzed by the neurotracker before the alarm is generated. All other frames will be interpolated. The higher the specified value, the more accurate the tracking, but the higher the CPU load.
In the Device drop-down list (5) select the device where the neutrotracker will operate:
Auto — automatic device selection.
CPU — central processing unit (not recommended).
Nvidia GPU (depends on the number of installed Nvidia video cards).
Click the Apply button (6).
Note
- If necessary, create and configure the VMDA detection tools on the basis of the neutrotracker. The procedure of creating and configuring the VMDA detection tools for a neurotracker is similar to creating and configuring the VMDA detection tools for a regular tracker; the only difference is that it is necessary to create the VMDA detectors for a neurotracker on the basis of the Neurotracker object, and not the Tracker object (for details, see Creating and configuring VMDA detection).
- If it is necessary to periodically generate the events containing the number of objects received from the neurotracker, then create and configure the neutrotracker track counter (see Configuring the neurotracker track counter).
The Neurotracker software module configuration is complete.