Documentation for Auto Intellect 5.5. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

The IntLab Module object settings panel contains the following interface elements:

The following table describes the elements of the IntLab Module object settings panel.

Parameter name

Parameter setting method

Description

Data type

Default value

Value range

1

Sensor drop-down list

Selecting the value in the list

Selecting Sensor object which is used for the carriage license plates recognition

List of accessible Sensor objects

Sensor 1

Depending on number of accessible Sensor objects

2Recognition event drop-down listSelecting the value in the listSelecting the event from sensor, on which the plate recognition result will be displayedList of available Sensor eventsClosed

Closed – the recognition result will be displayed on the Sensor closed event

Open – the recognition result will be displayed on the Sensor opened event

3Working mode drop-down listSelecting the value in the listSelecting working period used for recognition of carriages license platesList of accessible working modesRecognizer of railway passenger carriage numbers

Recognizer of railway passenger carriage numbers – is used for recognition of railway passenger carriage numbers

Recognizer of railway freight carriage numbers – is used for recognition of railway freight carriage numbers

Special mode allows recognition of UIC carriage numbers

4Fluid level detection drop-down listSelecting the value in the listSelecting the Fluid level detection object to use with the IntLab module. For details on this detection tool, refer to Detector Pack. User Guide (the most relevant version is available in AxxonSoft documentation repository).List of accessible Fluid level detection objects<none>Depending on number of created Fluid level detection objects
  • No labels