Configuring the Event Manager module is performed on the settings panel of the Event Manager object.

Note.

The ver. field shows the current version of the Event Manager module.

To configure the Event Manager module, do the following:

  1. Go to the settings panel of the Event manager object.
  2.  Specify parameters of location the Event manager interface window:
    1. Set the Fix position checkbox to fix the interface window at specified coordinates excepting possibility to move it in the screen (1). If the checkbox is set the interface window is displayed without heading and it is impossible to change size of window by markings and to close it.
    2. Set the Always on top checkbox if it's required to display the interface window on top of all opened windows (2).
    3. To configure position of the Event manager window, specify coordinates of the window's upper left corner in the X: and Y: fields and its width and height in the W: and H: fields (3).
    4. From the Monitor: drop-down list select the number of monitor in the system on which the Event Manager window is to be displayed (4).
  3. Click Protocol color button (5)
  4. In the Redefining fields by strings group set checkboxes close to those fields for which digital values stored in the database it's required to display as test (5). 
  5. In the Max. number of events in list: field specify the maximum number of events to be shown in the Event manager window (6). If you set the value to 0, the protocol located in the lower part of the Event Manager interface window will be hidden, and the area of the specified Template of displaying will be proportionally enlarged.
  6. From the Ignore event after: drop-down list select the time period after which event will be ignored by the Event manager module (7). If time period from the moment of event receiving exceeds the specified period then such events won't be displayed in the Event manager window. Select the Never value if it's required to display events of any period of limitation.
  7. From the Display parameters: drop-down list select the way of displaying section of the Event manager window containing parameters of user related to the event (8):
    1. Always — section of the Event manager window containing user parameters is displayed all the time. If event not relating to user is selected then this section will be empty.
    2. Never — section of the Event manager window containing user parameters is not displayed.
    3. If it's required — section of the Event manager window containing user parameters is displayed only if there is user related to the selected event. In this case only user parameters specified on the Field and Additional field tabs on settings panel of the Rule of displaying object (see the section) will display. If the informational event is selected or the corresponding user is not found then this section won't display.
  8. From the Selection of received events: drop-down list select the way of selection events requiring processing (9).
  9. Set the Delete after processing by operator checkbox if it's required to delete events that were already processed by the operator from the list and leave only current events (10).  
  10. Set the Select last informational event if all events are processed (depends on their selection) checkbox to select only last informational event (11).

    Note.

    If there is at least one unprocessed event the last informational event won't be selected.

  11. Set the Allow operator to clear the list of events checkbox to allow operator possibility to clear the list of events (12). To clear the list of event click the right mouse button on some event and select the Clear list value.
  12. From the Display window: drop-down list select the value determining the way of displaying the Event manager window. Select the Always value to display the window all the time. If it's required to activate window by event from device or hide it after finishing of operator actions, select the By event value (13).
  13. From the Time of window displaying drop-down list select time period during which the Event manager window will display after the event receiving (14).

    Note.

    Time of window displaying should be specified only if the By event way of window displaying is selected.

  14. To save changes click Apply button.

Configuring the Event manager module is completed.