The settings panel of the Camera object is shown in figures.

The Basic settings tab.

The Advanced settings tab.

The Streams settings tab.

The Main stream tab.

The Video stream tab.

Table describes the settings parameters of the Camera object.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values


1

The Identification number field *

Automatically

Shows the identification number of the Camera  system object in the system.

Sequence of numbers

-

From 1 to FaceCamOffset, by default FaceCamOffset = 50000.

FaceCamOffset value is set with the help of the registry key of the same name (see Registry keys reference guide).

2

The Name field *

Enter the value in the field

Set the name of the Camera object in the system

Latin, Cyrillic letters and service characters

Camera

A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

The Region drop-down list

Is selected from the list

Assigns the Section structural element, to which the given Camera object refers.

Name of the  Section objects registered in the system.

Section

Depends on the number of created Section objects registered in the system.

4

The Disable checkbox

Is set with a checkbox

Set the status (enabled or disabled) of the Camera object in the system.

Boolean type

No

Yes – the Camera object is disabled and is not in use.

No – the Camera object is enabled and is in use.

5

The Video Capture Device drop-down list

Is selected from the list

Set the parent Video Capture Device object for the given Camera object.

Name of the Video Capture Device objects registered in the system.

Name of the parent Video Capture Device object.

Depends on the number of the Video Capture Device objects in the system.

6

The Video box

Left-click

Displays video with settings.

A webpage of Web server of IP device appears in default browser when pressing and holding Shift (not available in Internet Explorer).

Video

-

-

The Basic settings tab

7

The Channel number drop-down list

Is selected from the list

Defines the number of the channel used to connect a video camera to the video capture card. Corresponds to the BNC-adapter number.

Sequence of numbers

1

Depends on the type of the  video capture card. Maximum 16 channels.

8

The Resolution drop-down list

Is selected from the list

Set the resolution of the frame.

List of available resolutions of the frames.

Standard

Standard.

High.

Full.

Particular values depend on the camera model.

9

The Recording quality slider

The slider is set in the required position

Set the quality of the recorded frame.

Is a value reciprocal to the level of video signal compression.

-

Above average

Min – maximum compression level and the lowest video signal quality.

Max – the lowest compression level and the highest video signal quality. 

10

The Color checkbox

Is set with a checkbox

Set the type of video image received from the camera (color or black and white)

Boolean type

Yes

Yes – the video will be color.

No – the video will be black and white.

11

The YUV 4:2:2 checkbox

Is set with a checkbox

Set the format of the video signal color image.

Boolean type

No

Yes – the video signal will be displayed in the YUV 4:2:2 format.

No – the video signal will be displayed in the YUV 4:2:0 format.

12

The Color slider

The slider is set in the required position

Set the color saturation of the colored video


From  maximum color saturation to a black and white video.

Average

Max – corresponds to the maximum color saturation of the video.

Min – corresponds to the black and white video.

13

The Brightness-Contrast checkbox

Is set with a checkbox

Set the mode for setting brightness and contrast of the video

Types of modes for setting brightness and contrast of the video

Automatic

Automatic (Position 1***)  - brightness and contrast are set automatically.

Manual (Position 2***)  - brightness and contrast are set manually.

Manual setting with automatic optimization (Position 3***)  - brightness and

contrast are set manually and followed by automatic optimization.

14

The Brightness slider

The slider is set in the required position

Set the video brightness

From maximum brightness (white video) to minimum brightness (black video)

Average

Max – corresponds to the maximum brightness of the video.

Min – corresponds to the minimum brightness of the video.

15

The Contrast slider

The slider is set in the required position

Set the video contrast

-

Average

Max – corresponds to the maximum contrast of the video.

Min – corresponds to the minimum contrast of the video.

16

The Size slider

The slider is set in the required position

Set the minimum object size triggering the main motion detector.

% in relation to the screen elevation

Average

Minimal – 0% of the video surveillance box size.

Maximum – 100% of the video surveillance box size

17

The Contrast slider

The slider is set in the required position

Set the minimal contrast of the object triggering the main motion detector

-

Less than average

Max – correspond to maximal contrast of the object

Min – corresponds to the minimal contrast of the object

18

The Record alarms checkbox

Is set with a checkbox

Starts automatic video recording on the alarm from the camera (alarm on the Main motion detector)

Boolean type

Yes

Yes – automatic video recording on the alarm from the camera is active.

No – automatic video recording on the alarm from the camera is not active.                                      

19The Number drop-down listIs selected from the listSets the number of Microphone audio from which is recorded simultaneously with video from the camera.Number of the Microphone objects registered in the system.-Depends on the number of the Microphone objects in the system.
20The Microphone drop-down listIs selected from the listSets the name of Microphone audio from which is recorded simultaneously with video from the camera.Name of the Microphone  objects registered in the system.-Depends on the number of the Microphone objects in the system.

21

The Pre-alarm record field

Enter the value in the field

Set the pre-alarm time period for video recording, during which there is pre-event recording

Time (in sec)

-

Recommended time – from 0 to 20

22

The Post-alarm record field

Enter the value in the field

Set the time period for video recording after alarm registration.

Time (in sec)

-

Recommended time – from 0 to 20

23

The Hot-record time field

Enter the value in the field

Set the time period from the alarm registration or the start of record, during which the frame rate of recording will comply with the value entered in the Hot record rate field

Time (in sec)

-

Recommended time – from 0 to 30

24

The Hot-record rate field

Enter the value in the field / select from the list

Set the frame rate of alarm’s  hot recording

fps

-


Depends on the capabilities of the camera.

Recommended time – from 0 to 20

25

The Recording frame rate field

Enter the value in the field/ select from the list

Set the frame rate for video recording

fps

-

Depends on the capabilities of the camera

Recommended time – from 1 to 25 for PAL

From 1 to 30 for NTSC

The Advanced settings tab

26

The Decompressor drop-down listIs selected from the list

Set the technology using which the compressed video stream will be decompressed while displaying video signal on the monitor.

Note. By default the parameter is not available for editing. To change the value of this parameter set the “1” value for the EnableCodecSettings registry parameter (see Registry keys reference guide).

The list of available decompressorsNo

BOSCH

FfmpegAllInOneDecoder

H263IppDecoder

H264InterlacedIppDecoder

H264IppDecoder

MJPEGIpp

Motion Wavelet 3.5

Motion Wavelet 7.1

MPEG2IppDecoder

MPEG4IppDecoder

MxPEG Mobotix

RGB24toYUV420

StreamLabs

VWV

WMVIppDecoder

27

The Compressor drop-down list

Is selected from the list

Set the algorithm of video stream compression 

Note. By default the parameter is not available for editing. To change the value of this parameter set the “1” value for the EnableCodecSettings registry parameter (see Registry keys reference guide).

The list of available algorithms

No

Depends on the camera model

28

The Estimate motion field

Enter the value in the field

Set threshold of camera’s sensivity to motion depending on the change of object’s brightness. Delta frame of video signal is created by this criterion. 

Sequence of numbers

7

From 2 to 255

29

The Key frames interval field

Enter the value in the field

Set the key frames rate.

Sequence of numbers

8

Depends on the capabilities of the camera

The Store at least group

30

The Store at least field

Enter the value in the field

Set the time period for keeping the video archive from the camera and also audio archive(with the synchro records) on the Server. Parameter allows saving the large archive for selected camera due to size of other cameras archive.

Note. It is better to set the Store at least parameter not for more than 30% of cameras as this setting is a RECOMMENDED one. If there is not enough space for recording the archive, the setting is ignored and recording is not stopped anyway.

If more than 10 cameras are created in the system, then while attempting to set this parameter for more than 30% of cameras in the system, the corresponding warning appears after the Apply button is pressed. It can be disabled using the NotifyAbout_arch_days registry key (see Registry keys reference guide).

Day

-

More than 1

31The Store at least dropdown listSelect value from the listSets units for time period specified in the Store at least fieldThe list of available time unitsDays

Days

Hours
The Store no longer group
32The Store no longer fieldEnter the value in the field

Sets the time period for storing the archive – when it is expired, the archive is removed.  

Note. The archive can be removed before the specified time if it is required for loop recording.
Day or hour depending on the value selected in the dropdown list-More than 1
33The Store no longer dropdown listSelect value from the listSets units for time period specified in the Store no longer fieldThe list of available time unitsDays

Days

Hours
Not in groups
34The Additional info fieldEnter the value in the fieldSet the information displayed on the monitor above the camera name. This information is added to the export file and when the frame is printed, as to the event log  The line not longer than 100 charactersBlank lineLatin, Cyrillic letters and service characters

35

The Type drop-down list

Is selected from the list

Set the type of the camera. The setting affects the type of the icons used to represent the camera on the map

The list of available camera types

-

Fisheye

PTZ

Standard

36

The Processing priority slider

The slider is set in the required position

Set the priority of video processing

The order of video processing

Normal

Normal – normal video procession order

1/3 – 1/3 procession order

1/2 – 1/2 procession order

37

The Recording priority slider

The slider is set in the required position

Set the priority of video processing in the recording mode

The order of video processing in the recording mode

Normal

Normal – normal video record order

1/3  – 1/3 procession order

1/2 – 1/2 procession order

All resources – all ADC resourses are in use for video recording

38

Rotation mode checkbox

Setting checkbox

Enables a function of rotation the video image displayed on the Video surveillance monitor 

Boolean type

No

Yes - rotation mode is enabled

No - rotation mode is disabled

39

Rotate on drop-down list

Select value from the list

Specifies an angle of video image rotation when the rotation mode is enabled

Numbers

0

0, 90, 180, 270

40The Lens type dropdown list

Select value in the list

Sets the type of lens in useSupported lens typesNo

No – select if there are no fisheye or anamorphic lenses on the camera.

Standard fisheye lens – select if there is a fisheye lens on the camera.

Autocalibration – select if there is a fisheye lens on the camera and auto detection of video conversion parameters in order to eliminate artifacts is to be performed.

A0*V, A1UST, A8TRT, B0QQV, B4QQV, B5SST, B6SST – types of panomorph lens.
41The Camera location dropdown list

Select value in the list

Sets the camera locationSupported camera location modesCeiling

Ceiling

Wall

Floor

42The Visible part fieldEntered into the fieldDefines the visible part of the frame on the Video Surveillance Monitor after the dewarp.Percentage

75% for Ceiling position

66%  for Wall position

Note. The default value may be not displayed.

0-100
Streams settings tab

43

Streams configuring checkbox

Checking the box

Enables the multistream feature

Boolean

No

True – multistreaming is enabled; different streams can be used for analytics, archiving, and display.

False – multistreaming is disabled; a single stream is used for analytics, archiving, and display.

44

# field

AutomaticallyShows the stream numberInteger-1-10
45Enabled checkboxChecking the boxSets the enabled streamsBooleanNo

Yes – the stream is in use

No – the stream is not in use

46

Default checkbox

Checking the box

Assigns the video stream to be displayed both as locally and on remote clients

List of available streams

No

Yes – the stream is in use by default

No – the stream is not in use by default


47

Video analytics checkbox

Checking the box

Assigns the video stream used  for video analytics (including main motion detection tool). This stream is used by all Intellect detection tools (except embedded video camera detection tools) – including tracking detection tools, motion detection tool, face detection tool, facial recognition tools and detection tools that are the part of Detector Pack.

List of available streams

No

Yes – the stream is in use for video analytics

No – the stream is not in use for video analytics

48

Archive checkbox

Checking the box

Sets video stream recorded to the archive not upon alarm – the continuous recording is performed.

List of available streams

No

Yes – the stream is in use for archive recording

No – the stream is not in use for archive recording

49Archive (alarms) checkbox
Checking the box Sets video stream recorded to the archive upon alarm.List of available streamsNo

Yes – the stream is in use for archive recording by alarm

No – the stream is not in use for archive recording by alarm

Main stream tab
50IP fieldEnter the value in the fieldSets the IP address from which the client will receive the video data from the ONVIF Server in the Multicast mode.IP address224.0.0.10224.0.0.0 - 239.255.255.255
51Port fieldEnter the value in the fieldSets the port for transmitting the video data in the Multicast mode.NumbersDepends on the number of cameras and streams in the system

Any valid non-busy port numbers.

The number of ports is determined by the system administrator.

Video stream tab

52

Purpose field

-

Displays a description of how the video stream is used

String

Depends on the video stream's designated purpose

Most Latin and Russian characters, numbers

53

Resolution dropdown list**

Selected from a list

Assigns the video stream's resolution

List of ­supported­ video­ resolutions

Standard

Standard

High

Full

Particular values depend on the camera model.

54

Speed spinbox**

Typed into a field

Assigns the frame rate of the video stream

Frame rate (fps)

25

Depends on the capabilities of the camera

55

Codec dropdown list**

Selected from a list

Assigns the technology to be used to encode and decode the video stream

List of supported codecs

Depends on the camera model

Depends on the camera model.

56

Key frame rate spinbox**

Typed into a field

Assigns the key frames rate.

Set of natural­ numbers

8

Depends on the capabilities of the camera

57

Video quality slider**

Moving it to a position

Assigns the frame quality

-

Maximum

Min – maximum compression and minimum video quality

Max – minimum compression and maximum video quality

58Lock disabling streams not in use checkboxSetting a checkbox

This checkbox is to be set checked if the purpose is not specified for the configured stream but is is in use for recording on command or script.

BooleanNo

Yes – if the stream value is not selected, then the stream is in the sleep mode and it cannot be in use for recording on command or script.

No – if the stream purpose is not selected, then it can be in use for recording on command or script.
59IP fieldEnter the value in the fieldSets the IP address from which the client will receive the video data from the ONVIF Server in the Multicast mode.IP address224.0.0.10224.0.0.0 - 239.255.255.255
60Port fieldEnter the value in the fieldSets the port for transmitting the video data in the Multicast mode.NumbersDepends on the number of cameras and streams in the system

Any valid unused port numbers.

The number of ports is determined by the system administrator.

*Name of the interface element is not shown on the setting panel

**Equivalent settings on the Basic Settings and Advanced settings tabs, as well as on the settings panel of the Video Capture Device object, are ignored.

*** Position 1 - 

Position 2 - 

Position 3 - 

  • No labels