Go to documentation repository
Documentation for Auto Intellect 5.6. Documentation for other versions of Intellect is available too.
Previous page Next page
Parking violation detection module object settings panel contains the following interface elements:
The following table describes the elements of the Parking violation detection object settings panel.
1 | PTZ device drop-down list | Selecting the value in the list | Selecting PTZ device object which will perform the passage between presets | List of accessible PTZ device objects | No | Depending on number of accessible PTZ device |
2 | Priority drop-down list | Selecting the value in the list | Selecting ptz priority | List of accessible priorities | Low | Low - low ptz priority Standard - middle ptz priority High - high ptz priority |
3 | Time of stop for recording field | Setting the value in the field | Set time interval during which the vehicle can be in the frame of the same preset until generating the Parking violation alarm. | Second | 30 | 0-99999 |
4 | Initial preset field | Setting the value in the field | Set the number of initial preset of ptz device | Whole nonnegative number | 1 | 1-99999 |
5 | Final preset field | Setting the value in the field | Set the number of final preset of ptz device | Whole nonnegative number | 10 | 1-99999 |
6 | Timeout field | Setting the value in the field | Set time interval after which passage to the next preset is performed | Second | 10 | 0-99999 |
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|
Overview
Content Tools