Documentation for Axxon Next 4.5.0 - 4.5.10. Documentation for other versions of Axxon Next is available too.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

To operate the neural counter, a camera must match the following requirements:

  1. Minimum resolution is at least 640х360 pixels.
  2. Frame rate is no less than 2 FPS (no less than 4 FPS is recommended).
  3. Objects must be visually separated from the background as well as from each other.
  4. Camera is mounted in no less than 3 meters above the ground, or on the ceiling.
  5. An object (its bounding rectangle) must occupy no less than 10% of the FOV.

Attention!

We cannot guarantee normal operation of the neural counter with a fisheye camera.