You can configure a Hikvision door via the Hikvision 26X Door, Hikvision 28X Door, and Hikvision K1T605XF Door objects configuration panel, which are created on the basis of the Hikvision 26X, Hikvision 28X, and Hikvision K1T605XF objects manually or automatically after reading the configuration of the corresponding controller (refer to Network settings of the Hikvision controller and Network settings of the Hikvision controller). As an example of Hikvision door configuration, let's consider a Hikvision 26X controller.
You can configure the Hikvision door as follows:
- Go to the settings panel of the Hikvision 26X Door object.
- In the Number drop-down list (1), you see the door ID number assigned by the Hikvision controller. You can not change this value.
- In the Door Name field (2), you can set the name of the door under which it will further appear in the ACFA Intellect integration module.
- Select a door's default state from the Door Magnetic drop-down list (3): Normal Closed for normally closed or Normal Opened for normally open.
- Select a push-to-exit button type from the Exit button type (4) drop-down list: Normal Closed for normally closed or Normal Opened for normally open.
- In the Unlock Time (5) field, you can set a time interval after which the door will be automatically re-locked.
- In the Unlock Time for Disabled Pass field (6), you can set a time interval during which the door will be opened for any Disabled card holder.
- In the Unlock Timeout Alarm field (7), you can set a time interval after which an alarm is initiated if the door is still open.
- In the Duress Code field (8), you can set a code to be applied when accessing the door under duress. This code opens the door while triggering the duress alarm. The duress code consists of 4 to 8 digits.
In the Super password field (9), you can set a super password for this door. The super password consists of 4 to 8 digits.
Note.
Duress Code and Super password shall not match each other or authentication password.
- In the Dismiss Code field (10), you can set a code for turning off all card readers associated with this door. The Dismiss code consists of 4 to 8 digits.
- Check the Locking Door When it Closed box (11) if the door has to be locked immediately after its closing. If the box is left unchecked, the door will be locked after the Unlock Time interval expires (see Step 6).
Check the Enable First Card Remain Open box (12) if you want to set the door to first card mode.
Note.
Several First Cards can be set for one door. The door is available for other users with any authorization type after the first card is swiped only.
From the First Card Mode drop-down list (13), select Disabled, Normal Open or Authorization.
Disabled turns off the first card mode.
Normal Open sets the door to remain open for the time interval specified in the Remain Open Duration, min field (see step 15).
Authorization sets the access point to accept any kind of authentication (except for super card, super password and duress card/code) only after the first card is authorized.Note.
The First Card authorization is valid for a current day only. The authorization expires in 24 hours on the current day. Re-swipe the same first card to disable the first card mode.
- In the Remain Open Duration, min field (14), you can set the time interval during which the door will remain open after the first card is read in Normal Open mode.
- In the Multiauthentication Swipe Time field (15), you can set a time-out interval between access requests in multiple card configuration (see Setting up multiple Hikvision cards).
- Click the Apply button (16) to save your settings.
The Hikvision door is now configured.