To configure face detection and temperature control, do the following:

  1. Add a Temperature Matrix Data object in the Embedded Detection Tools group.
  2. Under the newly added object, create a Face Detection and Temperature Control Detection Tool.
  3. Select temperature unit (1).
  4. To caption video with thermal data, do the following:
    1. Select Yes for the Show Thermal Overlay parameter (2).
    2. In the Preview window, drag anchor points to draw an area where thermal data should be displayed.
  5. If you use an Electromagnetic Radiation Absorber (BB), do the following:
    1. Specify its temperature (3). If temperature readings in this point are different, the bias will be used to re-calculate readings across all measurement points. 
    2. In the Preview window, double click to add anchor points  at the position of the electromagnetic radiation absorber (BB).
  6. If you have discovered that your readings differ from actual temperature values, add the offset value into the Temperature Value Offset field (4).  Bias values may be positive or negative. 

  7. The rest of this detection tool parameters are identical to those of the basic face detection tool (see ).
  8. Click the Apply button.

You have configured detection tool now.