Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

The settings panel of the SIP-panel object is shown in the figure.

The description of the SIP-panel interface object settings is shown in the table.

ParameterMethod for specifying the parameterParameter descriptionSymbolDefault valueRange of values
The Position tab

1


The X filed

Type-in the value in the field

Sets the coordinate in the X horizontal axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The Y field

Type-in the value in the field

Sets the coordinate in the Y vertical axis for the upper left corner of the SIP-panel interface object on the screen

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

2


The W filed

Type-in the value in the field

Sets the window width of the SIP-panel interface object

% of the screen width

-

From 0 to M*100, where M is the number of monitors installed

The H field

Type-in the value in the field

Sets the window height of the SIP-panel interface object

% of the screen height

-

From 0 to M*100, where M is the number of monitors installed

3The Monitor dropdown listSelect in the listSets the system ID of the monitor for which the coordinates are setIDs of the monitors in the OS1From 1 to 16
4The Terminal drop-down listSelect in the listSets the SIP-terminal object which SIP-devices use the SIP Panel.Name of the SIP Panel objects registered in the system-Depends on the number of the SIP Panel objects in the system
5The Monitor drop-downSelect in the listSets the the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added.Name of the Monitor objects registered in the system-Depends on the number of the Monitor objects in the system

6

The Display only when calling checkbox

Set the checkbox

Enables displaying of the SIP-panel interface box only at call

Boolean type

No

Yesthe SIP panel is only displayed during call.

Nothe SIP panel is always displayed.

7The New calls to end check boxSet the checkboxEnables adding new calls to the end of the list.Boolean typeNo

Yes – new calls are added to the end of the list.

No – new calls are added to the top of the list.

8The Mute keypress sound check boxSet the checkboxMutes the sound of keys clicked on the SIP panelBoolean typeNo

Yes – keypress sound disabled.

No – keypress sound is turned on.

9The Maximize screen on call check boxSet the checkboxEnables automatic display switching on callBoolean typeNoYeswhen a call is made to the SIP terminal corresponding to the SIP panel, the Display to which the SIP panel is added is automatically shown.

No – the displays are not switched automatically on any call to the SIP terminal corresponding to the SIP panel.

  • No labels