Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Method 1

http://example.com:[port]/web2/secure/video/image.jpg?cam.id=1&version=4.7.8.0

Parameters:
cam.id – required. Camera ID.
width – optional. Value can be in [64, 1600] range. Server automatically rounds width to larger value divisible by 4.
height – optional. Value can be in [30, 1200] range.
version – optional. client version (for protocol exchange). It's required to send "4.7.8.0" value now.
login – optional. Login;
password – optional. If password access is set.

Size of returned image is taken from video stream if width and height parameters are not set.

Returned value:
jpeg image of approximately requested size.

In case of error the http error code is returned:
404 – camera disabled or not in use (disabled);
403 – invalid password;
426 – old client version;
429 – too many requests;
444 – camera signal is lost or camera disabled (coaxial conductor disconnected from card);
503 – archive error.

Example:
Get image from camera 5, width is approximately 85 pixels:
http://localhost:8079/web2/secure/video/image.jpg?cam.id=5&width=85&version=4.7.8.0&login=username&password=secret

Jpg image of width 88 pixels or error code and zero length body (i.e. only headings) will be received in reply).

Method 2

http://example.com:[port]/web2/secure/video/action.do?version=4.9.0.0&command=frame.video&video_in=CAM:1&imageWidth=400&imageHeight=200

cam.id – camera ID.

sessionid – any value.

imageWidth – requested frame width.

imageHeight – requested frame height.

Example:

Receive a frame from Camera 1 with a height of 400 pixels.

http://192.168.0.79:8085/web2/secure/video/action.do?version=4.9.0.0&command=frame.video&video_in=CAM:1&imageWidth=400

  • No labels