The settings panel of the SIP-panel object is shown in the figure.
The description of the SIP-panel interface object settings is shown in the table.
№ | Parameter | Method for specifying the parameter | Parameter description | Symbol | Default value | Range of values |
---|---|---|---|---|---|---|
The Position group | ||||||
1 | The X field | Type-in the value in the field | Sets the coordinate in the X horizontal axis for the upper left corner of the SIP-panel interface object on the screen | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed |
The Y field | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the SIP-panel interface object on the screen | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed | |
2 | The W field | Type-in the value in the field | Sets the window width of the SIP-panel interface object | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed |
The H field | Type-in the value in the field | Sets the window height of the SIP-panel interface object | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed | |
3 | The Monitor dropdown list | Select in the list | Sets the system ID of the monitor for which the coordinates are set | IDs of the monitors in the OS | 1 | From 1 to 16 |
The Operator interface settings group | ||||||
4 | The Terminal drop-down list | Select in the list | Sets the SIP-terminal object which SIP-devices use the SIP Panel. | Name of the SIP Panel objects registered in the system | - | Depends on the number of the SIP Panel objects in the system |
5 | The Monitor drop-down | Select in the list | Sets the the Monitor object corresponding to the Video Surveillance Monitor to which the video cameras associated with the corresponding SIP-devices are added. | Name of the Monitor objects registered in the system | - | Depends on the number of the Monitor objects in the system |
The Interface behavior group | ||||||
6 | The Display only when calling checkbox | Set the checkbox | Enables displaying of the SIP-panel interface box only at call | Boolean type | No | Yes – the SIP panel is only displayed during call. No – the SIP panel is always displayed. |
7 | The New calls to the end check box | Set the checkbox | Enables adding new calls to the end of the list. | Boolean type | No | Yes – new calls are added to the end of the list. No – new calls are added to the top of the list. |
8 | The Disable keypress sound check box | Set the checkbox | Mutes the sound of keys clicked on the SIP panel | Boolean type | No | Yes – keypress sound disabled. No – keypress sound is turned on. |
9 | The Maximize screen on call check box | Set the checkbox | Enables automatic display switching on call | Boolean type | No | Yes – when a call is made to the SIP terminal corresponding to the SIP panel, the Display to which the SIP panel is added is automatically shown. No – the displays are not switched automatically on any call to the SIP terminal corresponding to the SIP panel. |
The Interface elements group | ||||||
10 | The Dial pad check box | Set the checkbox | Enables the display of the dial pad in the interface | Boolean type | Yes | Yes - the dial pad is displayed. No - the dial pad is hidden. |
The Caption check box | Set the checkbox | Enables the display of tab names in the interface. When disabled, only the Call tab will be displayed without displaying the name | Boolean type | Yes | Yes - the tab names are displayed. No - only the Call tab is displayed without displaying the name. | |
The Archive check box | Set the checkbox | Enables the display of the Archive tab in the interface | Boolean type | Yes | Yes - the Archive tab is displayed. No - the Archive tab is hidden. | |
The Call control buttons check box | Set the checkbox | Enables the display of the buttons at the bottom of the call control panel | Boolean type | Yes | Yes - call control buttons are displayed. No - call control buttons are hidden. |