This page lists integration modules with limited functionality implemented for specific projects. These modules are present in the ACFA-Intellect installer and are supported, but may not contain all the necessary functions. Please contact ITV | AxxonSoft technical support to clarify which features are supported.

Common name

Integrated hardware (name of devices)

Functionality/Restrictions

Name in price-list

Information on manufacturer

Way of integration

Hardware connection interface

ACFA-Intellect version
Anson DBAndy ME12Monitoring*INTELLECT Access Control Service (Anson), per system

INDI

andi-bg.com

low-level protocolEthernet-
AritechFP2000 seriesMonitoring, control/Multiple panels on one COM port are not supported (i.e. via converters like UN2011). Events from the panel are supported partially.INTELLECT Alarm Service (Aritech), per panel

Aritech 

www.aritech.pro

low-level protocolRS-2325.3
Impro

Impro (ECII) Ethernet Controller

Impro (iTRT) Intelligent Twin Reader Terminal

Impro (iTT) Intelligent Twin Antenna Terminal

Impro (MDTA) Multi-discipline Time Attendance
Terminal

Impro I16 16 Channel Input Terminal

Impro O16 16 Channel Output Terminal

Monitoring*INTELLECT Access Control and Fire Alarm Service (Impro), per terminal

Impro Technologies
http://www.impro.net/

SOFT-SOFTEthernet, RS4855.3
Hirsch Velocity
M8N, M2N, M16Monitoring*INTELLECT Access Control Service (HIRSCH Velocity), per reader

Identiv

https://www.identiv.com/

SOFT-SOFTEthernet5.4

Rakinda

RD007Monitoring and control of entrancesINTELLECT Access Control Service (Rakinda), per reader

Shenzhen Rakinda Technology Co., Ltd

5F Building A2 , Lee Lang Software Park, Bu Lan Road 31, Longgang District, Shenzhen City, Guangdong, China
Phone: +86 755 8323 3013
Email: wyp@rakinda.com
http://www.rakinda.com

SDKEthernet6.8
HundureHundure IM1000UIntegration is made for a specific project. The device is designed to encode Mifare cards. In the integration module, the code written to the card is generated according to a certain non-customizable algorithm.Licensed as control reader

HUNDURE

7F., No.10, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan
Phone+ 886 2 2999-2240, + 886 2 2999-2395
Email: overseas@hundure.com
http://www.hundure.com/

Low-level protocolRS-2326.8
ControlIDiDSecureOnly user import from iDSecure to Intellect databaseINTELLECT Database Import Service (Control ID)

ControlID

https://www.controlid.com.br

SOFT-SOFTEthernet6.9

Bosch APE

Only entrances connectable to Bosch Access Professional Edition (APE) softwareOnly monitoring and control of entrances

INTELLECT Access Control Service (Bosch APE Server), per system

INTELLECT Access Control Service (Bosch APE Entrance), per entrance

Bosch Sicherheitssysteme GmbH

https://www.boschsecurity.com/

SOFT-SOFT-6.9

*If only Monitoring is listed as supported function for ACS, this indicates that integration is not intended for widespread use, since the main function of any ACS integration is management of the user database and access levels in the ACS controllers.

  • No labels