The settings panel for the Incident manager interface object is shown in the figures. The description of the Incident manager parameters is given in the corresponding tables.
Filters tab
№ | Parameter | Parameter value setting method | Parameter description | Representation | Default value | Range of values |
1 | Identification number* field | Automatically | Displays the identification number of the Incident manager interface object in the system | Positive integers | - | Depends on the number of Incident manager objects in the system |
2 | Name* field | Type-in the value in the field | Sets the name of the Incident manager object in the system | Latin, Cyrillic and service characters | Incident manager | A string containing a sequence of any characters (letters, numbers, service characters except for > and <), case-insensitive. Number of characters - from 1 to 60 |
3 | Disable checkbox | Set the checkbox | Sets the state (enabled or disabled) of the Incident manager object in the system | Boolean type | No | Yes - the Incident manager object is disabled and not used No - the Incident manager object is enabled and in use |
4 | Display drop-down list | Select from the list | Sets the parent Display object for this Incident manager object | Names of Display objects created in the system | Name of parent Display object | Depends on the number of Display objects in the system |
5 | X field | Type-in the value in the field | Sets the coordinate of the upper left corner of the Incident manager interface window along the horizontal X axis | % relative to screen width | - | From 0 to M*100, where M is the number of installed monitors |
Y field | Type-in the value in the field | Sets the coordinate of the upper left corner of the Incident manager interface window along the vertical Y axis | % relative to screen height | - | From 0 to M*100, where M is the number of installed monitors | |
6 | W field | Type-in the value in the field | Sets the width of the Incident manager interface window | % relative to screen width | - | From 0 to M*100, where M is the number of installed monitors |
H field | Type-in the value in the field | Sets the height of the Incident manager interface window | % relative to screen height | - | From 0 to M*100, where M is the number of installed monitors | |
7 | Allow moving checkbox | Set the checkbox | Allows to manually change the position of the Incident manager window | Boolean type | No | Yes - allow to manually move the Incident manager window No - prohibit to manually move the Incident manager window |
8 | Х button | Click the button | Opens a test window for specifying the position of the Incident manager interface window | - | - | - |
9 | Monitor drop-down list | Select from the list | Defines the number of the monitor in the system for which the coordinates are being set | Monitor numbers in the operating system | 1 | From 1 to 16 |
Filters tab | ||||||
10 | Type drop-down list | Select from the list | Sets the type of objects for which the events should be displayed in the Incident manager window | Available object types | - | Depends on objects created in the system. Only those object types are available for selection for which the value "INFORMATION" or "ALARM" is selected on the Events tab in the Processing messages column in the ddi.exe utility (see The Events tab). |
11 | Number drop-down list | Select from the list | Sets the number of the object by which the events should be displayed in the Incident manager window | Positive integers | - | Depends on the number of objects of the specified type created in the system |
12 | Name drop-down list | Automatically | Sets the name of the object by which the events in the Incident manager window should be displayed | Names of objects created in the system | - | Depends on objects created in the system. |
13 | Event type drop-down list | Select from the list | Sets the events displayed in the Incident manager interface window | Events available to the selected object | - | Depends on the object type |
14 | Logic field | Type-in the value in the field | Specifies the logic that will be used to handle the events of the corresponding object | Logic name | - | A string containing a sequence of any characters (letters, numbers, service characters except for > and <), case-insensitive. Number of characters - from 1 to 255 |
15 | Priority field | Type-in the value in the field | Priority number for events of the corresponding object | Priority name | - | Numeric value, positive integer |
Without groups | ||||||
16 | Interfaces for escalations list | Set the checkbox | Specifies the Incident manager objects to which the operator can escalate events | List of Incident manager objects available in the system | - | Depends on the number of Incident manager objects created in the system |
Logic tab
№ | Parameter | Parameter value setting method | Parameter description | Representation | Default value | Range of values |
---|---|---|---|---|---|---|
1 | Editing logic list | Select from the list | The logic that was specified for the events of an object at the stage of configuring the event filter | List of created logics | - | Depends on the number of different logics |
2 | Starting checkbox | Set the checkbox | The element that will be displayed first for the operator when processing the event. To select the starting element:
| Boolean type | No | Yes - the element is the starting element in the logic. No - the element is not a starting element in logic. Only one element in the logic can be the starting one. |
3 | Element ID field | Type-in the value in the field | Element name | Latin, Cyrillic and service characters | - | From 0 to 255 characters |
4 | Element type field | Select from the list | Element type (see Configuring the elements) | Available element types | - | Image Button Comboboxes Comment Radio buttons Checkboxes |
5 | Edit button | Click the button | Opens a window for editing the selected element (see Configuring the elements) | - | - | - |
Main tab
№ | Parameter | Parameter value setting method | Parameter description | Representation | Default value | Range of values |
---|---|---|---|---|---|---|
1 | Data server field | Type-in the value in the field | Address of the server to which the data about the operator's actions in the Incident manager should be sent. Attention! This feature is not available in the current Intellect version. | - | - | - |
2 | Allow closing without processing checkbox | Set the checkbox | Enables the operator to close the events in the Incident manager without processing them. | Boolean type | No | Yes - the operator can close events without processing. No - the operator cannot close events without processing. |
3 | "In work" hotkey field | Type-in the value in the field | A hotkey, using which the operator can start processing the event. To set the hotkey, place the mouse cursor in the field and press the required key or key combination on the keyboard. | Keyboard keys | - | All possible keyboard keys and key combinations using Ctrl, Shift and Alt. |
4 | Map drop-down list | Select from the list | The Map object, which will be linked with the Incident manager. The operator can make the object with the event be highlighted on the map. | List of Map objects available in the system | - | Depends on the number of Map objects created in the system |
5 | Video drop-down list | Select from the list | Video display mode for archive and live video | Available display methods | ActiveX | ActiveX - archive will open in a separate window. Monitor - archive will open on the selected Surveillance Monitor. |
6 | Priority field | Type-in the value in the field | Priority number | Priority number | - | Numeric value, positive integer |
7 | Value field | Type-in the value in the field | Priority description. If the priority description is set, then it will be displayed in the Incident manager, otherwise the priority number will be displayed. | Priority description | - | A string containing a sequence of any characters (letters, numbers, service characters except for > and <), case-insensitive. Number of characters - from 1 to 255 |
8 | Column width fields | Type-in the value in the field | The width of the columns in the event handling interface in pixels or as a percentage of the entire width of the Incident manager interface. | Pixels or fractions | 150 pixels | Percentage values should be set in fractions of 1, for example, 0.25. If a value greater than 1 is specified, then it will be taken in pixels. |
9 | Number of columns field | Type-in the value in the field | Sets the number of columns when displaying the event processing logic in the Incident manager interface | Positive integers | 4 | >=0 |
Group by tab
№ | Parameter | Parameter value setting method | Parameter description | Representation | Default value | Range of values |
---|---|---|---|---|---|---|
1 | Filtering drop-down list | Select from the list | Sets the way of filtering events in the Incident manager | Available filtering methods | Operator | by operator — the operator can choose the filtering method in the Incident manager interface. by default — the event filtering is disabled. by region — the events are filtered by region. by event — the events are filtered by event type. by object — the events are filtered by object. |
2 | Process all filtered checkbox | Set the checkbox | Sets the ability to block events in a filtered group for processing by other operators in case if one operator has already started processing an event from the group. In this case, the events of the group are available for processing only by this operator. | Boolean type | No | Yes - events of the filtered group are blocked for other operators if one operator has already started processing an event from the group. No - events of the filtered group are not blocked if the operator has already started processing an event from the group. |
3 | Close all filtered checkbox | Set the checkbox | Sets the ability to close the entire filtered group of events when processing one event from the group | Boolean type | No | Yes - closing the filtered event group is enabled No - closing the filtered event group is disabled |
4 | Grouping in list drop-down list | Select from the list | Sets the way of grouping events | Available grouping methods | no grouping | no grouping - all events will be displayed in the event display window without grouping. If filtering is set, then all events of the selected filter will be displayed. by event - the events will be grouped by object type / object ID / event type / logic ID. |
5 | Show only first event in the group. Close others without processing checkbox | Set the checkbox | Sets the event display options within a group | Boolean type | No | Yes - only the first event from the group is displayed, the rest of the events are closed without processing after the first event is processed No - all events of the group are displayed |