In case of data of detections of «cold/hot» zones of a store from each store are received in the place of first level statistics generation and then processed data are received in the main server of statistics generation, do the following:

  1. Install the following program modules on each store: the Intellect software package, Intellect Detector Pack software package, Analytics Pack subsystem, Intellect Web Report System (if general distributed configuration is planned).
  2. Install the following program modules on the server of first level statistics generation: the Intellect software package, Analytics Pack subsystem, Intellect Web Report System, Intellect Detector Pack software package (if general distributed configuration is planned).
  3. Install the following program modules on the server of second level statistics generation which receives data from the server of first level statistics generation: the Intellect software package, Analytics Pack subsystem, Intellect Web report System, Intellect Detector Pack software package.

    Note.

    Using of general distributed configuration is not necessary for multilevel generation of statistics.

  4. Configure the RabbitMQ locally on the server of statistics generation of first and second levels (configuring the RabbitMQ is presented in the Configuring the RabbitMQ user section).
  5. Configure the RabbitMQ locally in each store (configuring of the RabbitMQ is presented in the Configuring the RabbitMQ application section).
  6. Configure detections of «cold/hot» zones of a store in each store (detail configuring of detections is presented in the Intellect Detector Pack. User Guide document).
  7. Configure the visitor behavior analysis reports on the basis of data received from detections in different stores (procedure of reports creating is presented in the Intellect Web Report System. User Guide document).