Go to documentation repository
When connecting the AGRG-IO-16/8-WD-DS sensor-relay cards, the electrical and technical specifications shown in the table below should be considered.
Parameter | Specification |
---|---|
Galvanic isolation on inputs/outputs | 3750 V |
Inputs | Quantity - 16 Type - current loop Galvanic isolation - Yes Maximum voltage - 60 V Rated voltage - 12 V Maximum current - 60 mA |
Outputs | Quantity - 8 Type - open collector Galvanic isolation - Yes Maximum voltage - 300 V Maximum current - 150 mA Minimum pick-up voltage - 1.0 V Minimum pick-up current - 5 mA |
Reset Timer (Watchdog) | Customizable |
Ping interval of all alarm inputs | 100 ms for all contacts. Customizable |
PC connection interface | USB 2.0, up to 5 meters |
Power supply | 500 mA consumption from USB port |